Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Special pages
Niidae Wiki
Search
Search
Appearance
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
Ringer equivalence number
Page
Discussion
English
Read
Edit
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
View history
General
What links here
Related changes
Page information
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
{{short description|Indication of the electrical load on a telephone line}} The '''ringer equivalence number''' ('''REN''') is a [[telecommunications]] [[measurement|measure]] that represents the [[electrical load]]ing effect of a [[telephone]] ringer on a [[telephone line]]. In the United States, '''ringer equivalence''' was first defined by [[U.S. Code of Federal Regulations]], [[Title 47 CFR Part 68|Title 47, Part 68]], based on the load that a standard [[Bell System]] [[model 500 telephone]] represented, and was later determined in accordance with specification ''ANSI/TIA-968-B'' (August 2009). Measurement systems analogous to the REN exist internationally. ==Definition== The ringer equivalence of 1 represents the loading effect of a single traditional telephone ringing [[electrical network|circuit]], such as that within the Western Electric [[model 500 telephone]]. The ringer equivalence of modern telephone equipment may be significantly lower than 1. For example, externally powered electronic ringing telephones may have a value as low as 0.1, while modern line-powered telephones, in which the ringer is powered from the telephone line, typically have a REN of approximately 0.8. In the United States, the FCC Part 68 specification defined REN 1 as equivalent to a 6930 [[Ohm (unit)|Ω]] [[resistor]] [[Series and parallel circuits|in series]] with an {{gaps|8|μF}} ([[Farad|microfarad]]) [[capacitor]]. The modern ANSI/TIA-968-B specification (August 2009) defines it as an [[electrical impedance|impedance]] of {{gaps|7000|Ω}} at {{gaps|20|Hz}} (type A ringer), or {{gaps|8000|Ω}} from {{gaps|15|Hz}} to {{gaps|68|Hz}} (type B ringer). ==Maximum ringer equivalence== The total ringer load on a [[subscriber]] line is the sum of the ringer equivalences of all [[information appliance|device]]s (phone, fax, a separate answerphone, etc.) connected to the line. This represents the overall loading effect of the subscriber equipment on the [[telephone exchange|central office]] ringing [[current (electricity)|current]] source. Subscriber telephone lines are usually limited to support a ringer equivalence of 5, per the federal specifications. If the total allowable ringer load is exceeded, the phone circuit may fail to ring or otherwise malfunction. For example, [[call waiting]], [[caller ID]], and [[ADSL]] services are often affected by high ringer load. Some [[analog telephone adapter]]s for [[Internet telephony]] require analog telephones with low REN, for example, the AT&T 210 is a basic phone which does not require an external electrical connection and has a REN of 0.9B. ==International specifications== [[File:Aansluitfactor.jpg|thumb|In the Netherlands all telephone equipment shall carry a blue label with the ringer equivalence number - in this case 1.5]] In the [[United Kingdom]] a maximum of 4 is allowed on any [[British Telecom]] (BT) line.<ref>{{cite web|url=http://www.britishtelephones.com/ren.htm|title=Ringer Equivalence Number (REN)|last=Anon|publisher=BOBS TELEPHONE FILE|access-date=28 May 2015}}</ref> In [[Australia]] a maximum of 3 is allowed on any [[Telstra]] or [[Optus]] Line.<ref>{{Cite book|url=https://www.telstra.com.au/content/dam/tcom/personal/help/pdf-b/017153a00-complete-home-cabling-guide.pdf |archive-url=https://ghostarchive.org/archive/20221009/https://www.telstra.com.au/content/dam/tcom/personal/help/pdf-b/017153a00-complete-home-cabling-guide.pdf |archive-date=2022-10-09 |url-status=live|title=Cabling of premises for telecommunications – A complete guide to home cabling|date=26 August 2013|publisher=Telstra Corporation|page=182}}</ref> In Canada it is called a ''load number'' (LN); which must not exceed 100. The LN of each device represents the percentage of total load allowed.{{citation needed|date=January 2014}} In Europe 1 REN used to be equivalent to an 1800 Ω resistor in series with a 1 μF capacitor. The latest [[ETSI]] specification (2003–09) calls for 1 REN to be greater than 16 kΩ at 25 Hz and 50 Hz. ==References== {{Reflist}} * {{FS1037C}} * [[American National Standards Institute|ANSI]]/[[TIA-968-B]] * [[European Telecommunications Standards Institute|ETSI]] TS 103 021 [[Category:Telephony equipment]] [[Category:Equivalent units]]
Summary:
Please note that all contributions to Niidae Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
Encyclopedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Templates used on this page:
Template:Citation needed
(
edit
)
Template:Cite book
(
edit
)
Template:Cite web
(
edit
)
Template:FS1037C
(
edit
)
Template:Gaps
(
edit
)
Template:Reflist
(
edit
)
Template:Short description
(
edit
)
Search
Search
Editing
Ringer equivalence number
Add topic