Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Special pages
Niidae Wiki
Search
Search
Appearance
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
Fibre Channel
Page
Discussion
English
Read
Edit
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
View history
General
What links here
Related changes
Page information
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
{{Short description|Computer storage networking technology}} {{Multiple issues| {{Technical|date=April 2024}} {{More citations needed|date=April 2024}} }} {{Fibre Channel}} '''Fibre Channel''' ('''FC''') is a high-speed data transfer protocol providing in-order, lossless<ref name="fibrechannel.org">{{cite web |url=http://fibrechannel.org/wp-content/uploads/2018/02/FCIA_Fibre_Channel_Performance_Congestion_Slowdrain_and_Over_Utilization_Final.pdf |title=Fibre Channel Performance: Congestion, Slow Drain, and Over Utilization, Oh My! |publisher=Fibre Channel Industry Association |date=February 6, 2018 |access-date=2018-02-28 |url-status=live |archive-url=https://web.archive.org/web/20180301164420/http://fibrechannel.org/wp-content/uploads/2018/02/FCIA_Fibre_Channel_Performance_Congestion_Slowdrain_and_Over_Utilization_Final.pdf |archive-date=2018-03-01 }}</ref> delivery of raw block data.<ref>{{cite web |url=https://images.apple.com/server/docs/Fibre_Channel_Basics_TB_v10.4.pdf |title=Fibre Channel Basics |publisher=Apple |access-date=2018-03-22 |url-status=live |archive-url=https://web.archive.org/web/20170829075557/http://images.apple.com/server/docs/Fibre_Channel_Basics_TB_v10.4.pdf |archive-date=2017-08-29 }}</ref> Fibre Channel is primarily used to connect [[computer data storage]] to [[Server (computing)|servers]]<ref name="Preston">{{cite book |last1=Preston |first1=W. Curtis |title=Using SANs and NAS |year=2002 |publisher=[[O'Reilly Media]] |location=Sebastopol, CA |isbn=978-0-596-00153-7 |oclc=472853124 |chapter=Fibre Channel Architecture |chapter-url=https://books.google.com/books?id=JUodwAQdMGcC&pg=PA19 |pages=19β39 }}</ref><ref name="Riabov">{{cite book |last1=Riabov |first1=Vladmir V. |editor1-first=Hossein |editor1-last=Bidgoli |title=The Internet Encyclopedia. Volume 3, P-Z |year=2004 |publisher=[[John Wiley & Sons]] |location=Hoboken, NJ |isbn=978-0-471-68997-3 |oclc=55610291 |chapter=Storage Area Networks (SANs) |chapter-url=https://books.google.com/books?id=5W3f6IyIBQcC&pg=PA329 |pages=329β338 }}</ref> in [[storage area network]]s (SAN) in commercial [[data center]]s. Fibre Channel networks form a [[switched fabric]] because the switches in a network operate in unison as one big switch. Fibre Channel typically runs on [[optical fiber]] cables within and between data centers, but can also run on copper cabling.<ref name="Preston" /><ref name="Riabov" /> Supported data rates include 1, 2, 4, 8, 16, 32, 64, and 128 [[gigabit per second]] resulting from improvements in successive technology generations. The industry now notates this as Gigabit Fibre Channel (GFC). There are various upper-level protocols for Fibre Channel, including two for block storage. [[Fibre Channel Protocol]] (FCP) is a protocol that transports [[Small Computer System Interface|SCSI]] commands over Fibre Channel networks.<ref name=Preston /><ref name=Riabov /> [[FICON]] is a protocol that transports [[ESCON]] commands, used by [[IBM mainframe]] computers, over Fibre Channel. Fibre Channel can be used to transport data from storage systems that use solid-state [[flash memory]] storage medium by transporting [[NVM Express|NVMe]] protocol commands. == Etymology == When the technology was originally devised, it ran over optical fiber cables only and, as such, was called "Fiber Channel". Later, the ability to run over copper cabling was added to the specification. In order to avoid confusion and to create a unique name, the industry decided to change the spelling and use the [[British English]] ''fibre'' for the name of the standard.<ref name=Tate>{{cite book |title=Introduction to Storage Area Networks |year=2016 |publisher=[[IBM]] |chapter=Fibre Channel internals |pages=33 }}</ref> == History == Fibre Channel is standardized in the [[Technical Committee T11|T11 Technical Committee]] of the International Committee for Information Technology Standards ([[INCITS]]), an [[American National Standards Institute]] (ANSI)-accredited standards committee. Fibre Channel started in 1988, with ANSI standard approval in 1994, to merge the benefits of multiple physical layer implementations including [[SCSI connector|SCSI]], [[HIPPI]] and [[ESCON]]. Fibre Channel was designed as a [[Serial communication|serial interface]] to overcome limitations of the SCSI and HIPPI physical-layer parallel-signal copper wire interfaces. Such interfaces face the challenge of, among other things, maintaining signal timing coherence across all the data-signal wires (8, 16 and finally 32 for SCSI, 50 for HIPPI) so that a receiver can determine when all the electrical signal values are "good" (stable and valid for simultaneous reception sampling). This challenge becomes evermore difficult in a mass-manufactured technology as data signal frequencies increase, with part of the technical compensation being ever reducing the supported connecting copper-parallel cable length. See [[Parallel SCSI]]. FC was developed with leading-edge [[multi-mode optical fiber]] technologies that overcame the speed limitations of the ESCON protocol. By appealing to the large base of SCSI disk drives and leveraging mainframe technologies, Fibre Channel developed [[economies of scale]] for advanced technologies and deployments became economical and widespread. Commercial products were released while the standard was still in draft.<ref name=ZG940168>[https://www-01.ibm.com/common/ssi/rep_ca/8/877/ENUSZG94-0168/index.html IBM 7319 Model 100 Fibre Channel Switch 16/266 and IBM Fibre Channel Adapter/266]</ref> By the time the standard was ratified lower speed versions were already growing out of use.<ref>Fibre Channel Physical and Signaling Interface (FC-PH) Rev 4.3, June 1, 1994</ref> Fibre Channel was the first serial storage transport to achieve gigabit speeds<ref>[https://www.pearsonhighered.com/assets/samplechapter/0/3/2/1/0321136500.pdf Tom Clark, Designing Storage Area Networks: A Practical Reference for Implementing Fibre Channel and IP SANs]</ref> where it saw wide adoption, and its success grew with each successive speed. Fibre Channel has doubled in speed every few years since 1996. {{Reflist|group=v}}In addition to a modern physical layer, Fibre Channel also added support for any number of "upper layer" protocols, including [[Asynchronous Transfer Mode|ATM]], [[Internet Protocol|IP]] ([[IPFC]]) and [[FICON]], with [[SCSI]] ([[Fibre Channel Protocol|FCP]]) being the predominant usage. Fibre Channel has seen active development since its inception, with numerous speed improvements on a variety of underlying transport media. The following tables shows the progression of native Fibre Channel speeds:<ref>{{cite web |title = Roadmaps |url = https://fibrechannel.org/roadmap/ |publisher = Fibre Channel Industry Association |access-date = 2023-03-05 }}</ref> {{mw-datatable}} {| class="wikitable sortable mw-datatable" style="margin: 1em auto 1em auto" |+ {{vanchor|Fibre Channel variants}}<ref name="Fibre Channel Speedmap">[https://fibrechannel.org/roadmap/ Fibre Channel Speedmap]</ref> ! Name ! Line-rate ([[Baud|gigabaud]]) ! Line coding ! Nominal throughput per direction {{nowrap|(MB/s)}} ! Market availability |- ! {{nowrap|133 Mbit/s}} | 0.1328125 | [[8b/10b encoding|8b10b]] | align="right" | 12.5 | 1993 |- ! {{nowrap|266 Mbit/s}} | 0.265625 | 8b10b | align="right" | 25 | 1994<ref name=ZG940168 /> |- ! {{nowrap|533 Mbit/s}} | 0.53125 | 8b10b | align="right" | 50 | {{dunno}} |- ! 1GFC (Gen 1) | 1.0625 | 8b10b | align="right" | 100 | 1997 |- ! 2GFC (Gen 2) | 2.125 | 8b10b | align="right" | 200 | 2001 |- ! 4GFC (Gen 3) | 4.25 | 8b10b | align="right" | 400 | 2004 |- ! 8GFC (Gen 4) | 8.5 | 8b10b | align="right" | 800 | 2008 |- ! 16GFC (Gen 5) | 14.025 | [[64b/66b encoding|64b66b]] | align="right" | 1,600 | 2011 |- ! 32GFC (Gen 6) | 28.05 | 256b257b | align="right" | 3,200 | 2016<ref name=g620release>Brocade 32Gb platform released, Storagereview.com {{cite web |url=http://www.storagereview.com/brocade_g620_gen_6_fibre_channel_switch_released |title=Brocade G620 Gen 6 Fibre Channel Switch Released |date=March 2016 |access-date=2016-04-04 |url-status=live |archive-url=https://web.archive.org/web/20160404014046/http://www.storagereview.com/brocade_g620_gen_6_fibre_channel_switch_released |archive-date=2016-04-04 }}</ref> |- ! 64GFC (Gen 7) | 28.9 | 256b257b (FC-FS-5) | align="right" | 6,400 | 2020 |- ! 128GFC (Gen 8) | 56.1<ref>[https://fibrechannel.org/wp-content/uploads/2023/06/FCIA-128GFC-Webcast-Final-v1.pdf 128GFC: A Preview of the New Fibre Channel Speed]</ref> |256b257b | align="right" | 12,800 |Planned 2025 |} FC used throughout all applications for Fibre Channel infrastructure and devices, including edge and ISL interconnects. Each speed maintains backward compatibility at least two previous generations (I.e., 32GFC backward compatible to 16GFC and 8GFC) {{mw-datatable}} {| class="wikitable sortable mw-datatable" style="margin: 1em auto 1em auto" |+ {{vanchor|Inter-Switch Link variants}}<ref name="Fibre Channel Speedmap"/> ! Name ! Line-rate ([[Baud|gigabaud]]) ! Line coding ! Nominal throughput per direction {{nowrap|(MB/s)}} ! Market availability |- ! 10GFC | 10.51875 | 64b66b | align="right" | 1,200 | 2009 |- ! 128GFC (Gen 6) | 28.05 Γ 4 | 256b257b | align="right" | 12,800 | 2016<ref name=g620release /> |- ! 256GFC (Gen 7) | 28.9 Γ 4 | 256b257b | align="right" | 25,600 | 2020 |} Inter-Switch Links, ISLs, are usually multi-lane interconnects used for non-edge, core connections, and other high speed applications demanding maximum bandwidth. ISLβs utilize high bit-rates to accommodate the funneling of edge connections. Some ISL solutions are vendor-proprietary. ==Characteristics== Two major characteristics of Fibre Channel networks are in-order delivery and lossless delivery of raw block data. Lossless delivery of raw data block is achieved based on a credit mechanism.<ref name="fibrechannel.org"/> ==Topologies== There are three major Fibre Channel topologies, describing how a number of [[computer port (software)|ports]] are connected together. A ''port'' in Fibre Channel terminology is any entity that actively communicates over the network, not necessarily a [[computer port (hardware)|hardware port]]. This port is usually implemented in a device such as disk storage, a Host Bus Adapter ([[host bus adapter|HBA]]) network connection on a server or a [[fibre channel switch|Fibre Channel switch]].<ref name=Preston /> [[File:Point-to-Point topology.svg|thumb|320px|right|alt=Point-to-Point topology connection using N ports|Topology diagram of a Fibre Channel point-to-point connection]] * '''{{visible anchor|Point-to-point}}''' (see ''FC-FS-3''). Two devices are connected directly to each other using [[#Ports|N_ports]]. This is the simplest topology, with limited connectivity.<ref name=Preston /> The bandwidth is dedicated. * '''[[Arbitrated loop]]''' (see ''FC-AL-2''). In this design, all devices are in a loop or ring, similar to [[Token Ring]] networking. Adding or removing a device from the loop causes all activity on the loop to be interrupted. The failure of one device causes a break in the ring. Fibre Channel hubs exist to connect multiple devices together and may bypass failed ports. A loop may also be made by cabling each port to the next in a ring. ** A minimal loop containing only two ports, while appearing to be similar to point-to-point, differs considerably in terms of the protocol. ** Only one pair of ports can communicate concurrently on a loop. ** Maximum speed of 8GFC. ** Arbitrated Loop has been rarely used after 2010 and its support is being discontinued for new gen switches. * '''[[Fibre Channel fabric|Switched Fabric]]''' (see ''FC-SW-6''). In this design, all devices are connected to [[fibre channel switch|Fibre Channel switch]]es, similar conceptually to modern [[Ethernet]] implementations. Advantages of this topology over point-to-point or Arbitrated Loop include: ** The Fabric can scale to tens of thousands of ports. ** The switches manage the state of the Fabric, providing optimized paths via Fabric Shortest Path First (FSPF) data routing protocol. ** The traffic between two ports flows through the switches and not through any other ports like in Arbitrated Loop. ** Failure of a port is isolated to a link and should not affect operation of other ports. ** Multiple pairs of ports may communicate simultaneously in a Fabric. {| class="wikitable sortable" style="margin: 1em auto 1em auto" |- ! Attribute ! Point-to-point ! Arbitrated loop ! Switched fabric |- ! Max ports || 2 || 127 || ~16777216 (2<sup>24</sup>) |- ! Address size | {{N/A}} || 8-[[bit]] ALPA || 24-bit port ID |- ! Side effect of port failure || Link fails || Loop fails (until port bypassed) || {{N/A}} |- ! Access to medium || Dedicated || Arbitrated || Dedicated |} == Layers == [[File:Fibre Channel layers.svg|thumb|Fibre Channel is a layered technology that starts at the physical layer and progresses through the protocols to the upper-level protocols like SCSI and SBCCS.]] Fibre Channel does not follow the [[OSI model]] layering, and is split into five layers: * '''FC-4''' β Protocol-mapping layer, in which upper-level protocols such as [[NVM Express]] (NVMe), [[SCSI]], IP, and [[FICON]] are encapsulated into Information Units (IUs) for delivery to FC-2. Current FC-4s include FCP-4, FC-SB-5, and [[NVMe#NVMe-oF|FC-NVMe]]. * '''FC-3''' β Common services layer, a thin layer that could eventually implement functions like [[encryption]] or [[RAID]] redundancy algorithms; multiport connections; * '''FC-2''' β Signaling Protocol, defined by the ''Fibre Channel Framing and Signaling'' standard, consists of the low level [[Fibre Channel network protocols]]; port to port connections; * '''FC-1''' β Transmission Protocol, which implements [[line coding]] of signals; * '''FC-0''' β [[physical layer]], defined by ''Fibre Channel Physical Interfaces'' standard, includes cabling, [[fibre channel electrical interface|connectors]] etc.; Fibre Channel products are available at 1, 2, 4, 8, 10, 16 and 32 and {{nowrap|128 Gbit/s}}; these protocol flavors are called accordingly 1GFC, 2GFC, 4GFC, 8GFC, 10GFC, 16GFC, 32GFC or 128GFC. The 32GFC standard was approved by the INCITS T11 committee in 2013, and those products became available in 2016. The 1GFC, 2GFC, 4GFC, 8GFC designs all use [[8b/10b encoding]], while the 10GFC and 16GFC standard uses [[64B/66B encoding|64b/66b encoding]]. Unlike the 10GFC standards, 16GFC provides backward compatibility with 4GFC and 8GFC since it provides exactly twice the throughput of 8GFC or four times that of 4GFC. ==Ports== [[File:Fibre Channel Topologies.svg|thumb|FC topologies and port types: This diagram shows how N_Ports can be connected to a fabric or to another N_Port. A Loop Port (L_Port) communicates through a shared loop and is rarely used anymore.]] Fibre Channel ports come in a variety of logical configurations. The most common types of ports are: * '''N_Port (Node port)''' An N_Port is typically an HBA port that connects to a switch's F_Port or another N_Port. Nx_Port communicating through a PN_Port that is not operating a Loop Port State Machine.<ref name="FC-FS-4" /> * '''F_Port (Fabric port)''' An F_Port is a switch port that is connected to an N_Port.<ref name="FC-SW-6" /> * '''E_Port (Expansion port)''' Switch port that attaches to another E_Port to create an Inter-Switch Link.<ref name="FC-SW-6" /> Fibre Channel Loop protocols create multiple types of Loop Ports: * '''L_Port (Loop port)''' FC_Port that contains Arbitrated Loop functions associated with the Arbitrated Loop topology.<ref name="FC-SW-6" /> * '''FL_Port (Fabric Loop port)''' L_Port that is able to perform the function of an F_Port, attached via a link to one or more NL_Ports in an Arbitrated Loop topology.<ref name="FC-SW-6" /> * '''NL_Port (Node Loop port)''' PN_Port that is operating a Loop port state machine.<ref name="FC-SW-6" /> If a port can support loop and non-loop functionality, the port is known as: * '''Fx_Port''' switch port capable of operating as an F_Port or FL_Port.<ref name="FC-FS-4" /> * '''Nx_Port''' end point for Fibre Channel frame communication, having a distinct address identifier and Name_Identifier, providing an independent set of FC-2V functions to higher levels, and having the ability to act as an Originator, a Responder, or both.<ref name="FC-FS-4" /> [[File:FC-platform-vnode.svg|360px|thumb|A Port has a physical structure as well as logical or virtual structure. This diagram shows how a virtual port may have multiple physical ports and vice versa.]] Ports have virtual components and physical components and are described as: * '''PN_Port''' entity that includes a Link_Control_Facility and one or more Nx_Ports.<ref name="FC-SW-6" /> * '''VF_Port (Virtual F_Port)''' instance of the FC-2V sublevel that connects to one or more VN_Ports.<ref name="FC-SW-6" /> * '''VN_Port (Virtual N_Port)''' instance of the FC-2V sublevel. VN_Port is used when it is desired to emphasize support for multiple Nx_Ports on a single Multiplexer (e.g., via a single PN_Port).<ref name="FC-FS-4" /> * '''VE_Port (Virtual E_Port)''' instance of the FC-2V sublevel that connects to another VE_Port or to a B_Port to create an Inter-Switch Link.<ref name="FC-SW-6" /> The following types of ports are also used in Fibre Channel: * '''A_Port (Adjacent port)''' combination of one PA_Port and one VA_Port operating together.<ref name="FC-SW-6">Fibre Channel - Switch Fabric 6 (FC-SW-6)</ref> * '''B_Port (Bridge Port)''' Fabric inter-element port used to connect bridge devices with E_Ports on a Switch.<ref name="FC-FS-4">[https://webstore.ansi.org/standards/incits/incits4882016 Fibre Channel - Framing and Signaling - 4 (FC-FS-4)]</ref> * '''D_Port (Diagnostic Port)''' A configured port used to perform diagnostic tests on a link with another D_Port.<ref name="BCFA Nutshell" /> * '''EX_Port''' A type of E_Port used to connect to an FC router fabric.<ref name="BCFA Nutshell" /> * '''G_Port (Generic Fabric port)''' Switch port that may function either as an E_Port, A_Port, or as an F_Port.<ref name="FC-SW-6" /> * '''GL_Port (Generic Fabric Loop port)''' Switch port that may function either as an E_Port, A_Port, or as an Fx_Port.<ref name="FC-SW-6" /> * '''PE_Port''' LCF within the Fabric that attaches to another PE_Port or to a B_Port through a link.<ref name="FC-FS-4" /> * '''PF_Port''' LCF within a Fabric that attaches to a PN_Port through a link.<ref name="FC-FS-4" /> * '''TE_Port (Trunking E_Port) A trunking expansion port that''' expands the functionality of E ports to support VSAN trunking, Transport quality of service (QoS) parameters, and Fibre Channel trace (fctrace) feature.<ref>{{Cite web|url=https://www.cisco.com/c/en/us/td/docs/switches/datacenter/mds9000/sw/4_1/configuration/guides/fm_4_1/fmguide.html|title=Cisco MDS 9000 Family Fabric Manager Configuration Guide, Release 4.x|date=November 11, 2013|publisher=Cisco Systems, Inc.|access-date=June 28, 2016|url-status=live|archive-url=https://web.archive.org/web/20160821064642/https://www.cisco.com/c/en/us/td/docs/switches/datacenter/mds9000/sw/4_1/configuration/guides/fm_4_1/fmguide.html|archive-date=August 21, 2016}}</ref> * '''U_Port''' '''(Universal port)''' A port waiting to become another port type<ref name="BCFA Nutshell">{{Cite web|url=https://www.brocade.com/content/dam/common/documents/content-types/education-study-tools/brocade-bcfa-nutshell-certification-study-tools.pdf|title=BCFA in a Nutshell Study Guide for Exam|date=February 2014|publisher=Brocade Communications, Inc.|access-date=June 28, 2016|url-status=live|archive-url=https://web.archive.org/web/20150907185312/http://www.brocade.com/content/dam/common/documents/content-types/education-study-tools/brocade-bcfa-nutshell-certification-study-tools.pdf|archive-date=September 7, 2015}}</ref> * '''VA_Port (Virtual A_Port)''' instance of the FC-2V sublevel of Fibre Channel that connects to another VA_Port.<ref name="FC-SW-6" /> * '''VEX_Port''' VEX_Ports are no different from EX_Ports, except underlying transport is IP rather than FC.<ref name="BCFA Nutshell" /> ==Media and modules== {{Missing information|section|legacy copper interfaces|date=November 2023}}{{Contradict section|date=November 2023}} [[File:Fibre Channel Media and Modules.png|thumb|Fibre Channel predominantly uses SFP or SFP+ modules with LC connector and duplex cabling, but 128GFC uses QSFP28 modules with MPO connectors and ribbon cabling.]] The Fibre Channel physical layer is based on serial connections that use fiber optics to copper between corresponding pluggable modules. The modules may have a single lane, dual lanes or quad lanes that correspond to the SFP, SFP-DD and QSFP form factors. Fibre Channel does not use 8- or 16-lane modules (like CFP8, QSFP-DD, or COBO used in 400GbE) and there are no plans to use these expensive and complex modules. The [[small form-factor pluggable transceiver]] (SFP) module and its enhanced version SFP+, SFP28 and SFP56 are common form factors for Fibre Channel ports. SFP modules support a variety of distances via multi-mode and [[single-mode optical fiber]] as shown in the table below. SFP modules use duplex fiber cabling with LC connectors. [[File:SFP-DD SMT 17c.png|thumb|SFP-DD modules are used in high-density applications that need to double the throughput of traditional SFP ports.]] SFP-DD modules are used for high-density applications that need to double the throughput of an SFP Port. SFP-DD is defined by the SFP-DD MSA and enables breakout to two SFP ports. Two rows of electrical contacts enable doubling the throughput of SFP modules in a similar fashion as QSFP-DD. The [[QSFP|quad small form-factor pluggable]] (QSFP) module began being used for switch inter-connectivity and was later adopted for use in 4-lane implementations of Gen-6 Fibre Channel supporting 128GFC. QSFP uses either LC connectors for 128GFC-CWDM4 or MPO connectors for 128GFC-SW4 or 128GFC-PSM4. MPO cabling uses 8- or 12-fiber cabling infrastructure that connects to another 128GFC port or may be broken out into four duplex LC connections to 32GFC SFP+ ports. Fibre Channel switches use either SFP or QSFP modules. {| class="wikitable sortable" |- ! Fiber type ! Speed {{nowrap|(MB/s)}} ! Transmitter<ref>Transmitter values listed are the currently specified values for the variant listed. Some older versions of the FC standards listed slightly different values (however, the values listed here fall within the +/β variance allowed). Individual variations for each specification are listed in the references associated with those entries in this table. FC-PH = X3T11 Project 755D; FC-PH-2 = X3T11 Project 901D; FC-PI-4 = INCITS Project 1647-D; FC-PI-5 = INCITS Project 2118D. Copies are available from [http://www.incits.org/ INCITS] {{webarchive|url=https://web.archive.org/web/20100915022630/http://www.incits.org/ |date=2010-09-15 }}.</ref> ! Medium variant ! Distance |- ! rowspan="17" |Single-mode fiber (SMF) | rowspan="2" |12,800 |1,310 nm longwave light |128GFC-PSM4 |0.5m - 0.5 km |- |1,270, 1,290, 1,310 and 1,330 nm longwave light |128GFC-CWDM4 |0.5 m β 2 km |- |6,400 |1,310 nm longwave light |64GFC-LW |0.5m - 10 km |- |3,200 |1,310 nm longwave light |3200-SM-LC-L |0.5 m - 10 km |- | rowspan="2" | 1,600 | 1,310 nm longwave light<ref group="ITS" name="FC-PI-5 Clause 6.3">FC-PI-5 Clause 6.3</ref> | 1600-SM-LC-L<ref group="ITS" name="FC-PI-5 Clause 8.1">FC-PI-5 Clause 8.1</ref> || 0.5 m{{snd}}10 km |- | 1,490 nm longwave light<ref group="ITS" name="FC-PI-5 Clause 6.3" /> | 1600-SM-LZ-I<ref group="ITS" name="FC-PI-5 Clause 8.1" /> || 0.5 m{{snd}}2 km |- | rowspan="2" | 800 | rowspan="2" | 1,310 nm longwave light<ref group="ITS" name="FC-PI-4 Clause 6.3">FC-PI-4 Clause 6.3</ref> | 800-SM-LC-L<ref group="ITS" name="FC-PI-4 Clause 8.1">FC-PI-4 Clause 8.1</ref> || 2 m{{snd}}10 km |- | 800-SM-LC-I<ref group="ITS" name="FC-PI-4 Clause 8.1" /> || 2 m{{snd}}1.4 km |- | rowspan="3" | 400 | rowspan="3" | 1,310 nm longwave light<ref group="ITS" name="FC-PI-4 Clause 6.3" /><ref group="ITS" name="FC-PH-2 lists 1300nm (see clause 6.1 and 8.1)">FC-PH-2 lists 1300nm (see clause 6.1 and 8.1)</ref> || 400-SM-LC-L<ref group="ITS" name="FC-PI clause 8.1">FC-PI clause 8.1</ref> || 2 m{{snd}}10 km |- || 400-SM-LC-M<ref group="ITS" name="FC-PI-4 Clause 8.1" /> || 2 m{{snd}}4 km |- || 400-SM-LL-I<ref group="ITS" name="FC-PH-2 clause 8.1">FC-PH-2 clause 8.1</ref> || 2 m{{snd}}2 km |- | rowspan="3" | 200 | 1,550 nm longwave light<ref group="ITS" name="FC-PI-4 Clause 11">FC-PI-4 Clause 11</ref> | 200-SM-LL-V<ref group="ITS" name="FC-PI-4 Clause 11" /> || 2 m{{snd}}50 km |- | rowspan="2" | 1,310 nm longwave light<ref group="ITS" name="FC-PH-2 lists 1300nm (see clause 6.1 and 8.1)" /><ref group="ITS" name="FC-PI-4 Clause 6.3" />|| 200-SM-LC-L<ref group="ITS" name="FC-PI clause 8.1" /> || 2 m{{snd}}10 km |- | 200-SM-LL-I<ref group="ITS" name="FC-PH-2 clause 8.1" /> || 2 m{{snd}}2 km |- | rowspan="3" | 100 | 1,550 nm longwave light<ref group="ITS" name="FC-PI-4 Clause 11" /> | 100-SM-LL-V<ref group="ITS" name="FC-PI-4 Clause 11" /> || 2 m{{snd}}50 km |- | rowspan="2" | 1,310 nm longwave light<ref group="ITS">FC-PH lists 1300nm (see clause 6.1 and 8.1)</ref><ref group="ITS" name="FC-PI-4 Clause 6.3" /> | 100-SM-LL-L<ref group="ITS" name="FC-PH Clause 8.1">FC-PH Clause 8.1</ref><br/>100-SM-LC-L<ref group="ITS" name="FC-PI clause 8.1" /> || 2 m{{snd}}10 km |- | 100-SM-LL-I<ref group="ITS" name="FC-PH Clause 8.1" /> || 2 m{{snd}}2 km |- ! rowspan="23" |Multi-mode fiber (MMF) |12,800 | rowspan="23" |850 nm shortwave light<ref group="ITS">FC-PI-5 Clause 6.4</ref><ref group="ITS">FC-PI-4 Clause 6.4</ref><ref group="ITS">The older FC-PH and FC-PH-2 list 850nm (for 62.5ΞΌm cables) and 780nm (for 50ΞΌm cables)(see clause 6.2, 8.2, and 8.3)</ref> |128GFC-SW4 |0β100 m |- |6,400 |64GFC-SW |0β100 m |- |3,200 |3200-SN |0β100 m |- | rowspan="4" | 1,600 | 1600-M5F-SN-I<ref group="ITS" name="FC-PI-5 Clause 8.2">FC-PI-5 Clause 8.2</ref> || 0.5β125 m |- | 1600-M5E-SN-I<ref group="ITS" name="FC-PI-5 Clause 8.2" /> || 0.5β100 m |- | 1600-M5-SN-S<ref group="ITS" name="FC-PI-5 Clause 8.2" /> || 0.5β35 m |- | 1600-M6-SN-S<ref group="ITS">FC-PI-5 Annex A</ref> || 0.5β15 m |- | rowspan="4" | 800 | 800-M5F-SN-I<ref group="ITS" name="FC-PI-5 Clause 8.2" /> || 0.5β190 m |- | 800-M5E-SN-I<ref group="ITS" name="FC-PI-4 Clause 8.2">FC-PI-4 Clause 8.2</ref> || 0.5β150 m |- | 800-M5-SN-S<ref group="ITS" name="FC-PI-4 Clause 8.2" /> || 0.5β50 m |- | 800-M6-SN-S<ref group="ITS" name="FC-PI-4 Clause 8.2" /> || 0.5β21 m |- | rowspan="4" | 400 | 400-M5F-SN-I<ref group="ITS" name="FC-PI-5 Clause 8.2" /> || 0.5β400 m |- | 400-M5E-SN-I<ref group="ITS" name="FC-PI-4 Clause 8.2" /> || 0.5β380 m |- | 400-M5-SN-I<ref group="ITS" name="FC-PI Clause 8.2">FC-PI Clause 8.2</ref> || 0.5β150 m |- | 400-M6-SN-I<ref group="ITS" name="FC-PI Clause 8.2" /> || 0.5β70 m |- | rowspan="3" | 200 | 200-M5E-SN-I<ref group="ITS" name="FC-PI-4 Clause 8.2" /> || 0.5β500 m |- | 200-M5-SN-I<ref group="ITS" name="FC-PI Clause 8.2" /> || 0.5β300 m |- | 200-M6-SN-I<ref group="ITS" name="FC-PI Clause 8.2" /> || 0.5β150 m |- | rowspan="5" | 100 | 100-M5E-SN-I<ref group="ITS">PC-PI-4 Clause 8.2</ref> || 0.5β860 m |- | 100-M5-SN-I<ref group="ITS" name="PC-PI Clause 8.2">PC-PI Clause 8.2</ref> || 0.5β500 m |- | 100-M6-SN-I<ref group="ITS" name="PC-PI Clause 8.2"/> || 0.5β300 m |- | 100-M5-SL-I<ref group="ITS" name="PC-PI Clause 8.2"/> || 2β500 m |- | 100-M6-SL-I<ref group="ITS">FC-PH Annex C and Annex E</ref> || 2β175 m |} {| class="wikitable sortable" |- ! Multi-mode fiber !! Fiber diameter !! FC media designation |- ! OM1 || 62.5 ΞΌm || M6 |- ! OM2 || 50 ΞΌm || M5 |- ! OM3 || 50 ΞΌm || M5E |- ! OM4 || 50 ΞΌm || M5F |- ! OM5 || 50 ΞΌm || N/A |} Modern Fibre Channel devices support [[Small form-factor pluggable transceiver|SFP+]] transceiver, mainly with [[Optical fiber connector|LC]] (Lucent Connector) fiber connector. Older 1GFC devices used [[GBIC]] transceiver, mainly with [[Optical fiber connector|SC]] (Subscriber Connector) fiber connector. ==Storage area networks== [[File:Fibre Channel Storage Area Network.png|thumb|The Fibre Channel SAN connects servers to storage via Fibre Channel switches.]] The goal of Fibre Channel is to create a [[storage area network]] (SAN) to connect servers to storage. The SAN is a dedicated network that enables multiple servers to access data from one or more storage devices. [[Enterprise storage]] uses the SAN to backup to secondary storage devices including [[disk arrays]], [[tape library|tape libraries]], and other backup while the storage is still accessible to the server. Servers may access storage from multiple storage devices over the network as well. SANs are often designed with dual fabrics to increase fault tolerance. Two completely separate fabrics are operational and if the primary fabric fails, then the second fabric becomes the primary. ==Switches== [[File:Fibre Channel Director.jpg|thumb|301x301px|Fibre Channel director with SFP+ modules and LC [[optical fiber connector]]s with Optical Multimode 3 (OM3) fiber (aqua)]] Fibre Channel switches can be divided into two classes. These classes are not part of the standard, and the classification of every switch is a marketing decision of the manufacturer: * '''Directors''' offer a high port-count in a modular (slot-based) chassis with no single point of failure (high availability). * '''Switches''' are typically smaller, fixed-configuration (sometimes semi-modular), less redundant devices. A fabric consisting entirely of one vendors products is considered to be ''homogeneous''. This is often referred to as operating in its "native mode" and allows the vendor to add proprietary features which may not be compliant with the Fibre Channel standard. If multiple switch vendors are used within the same fabric it is ''heterogeneous'', the switches may only achieve adjacency if all switches are placed into their interoperability modes. This is called the "open fabric" mode as each vendor's switch may have to disable its proprietary features to comply with the Fibre Channel standard. Some switch manufacturers offer a variety of interoperability modes above and beyond the "native" and "open fabric" states. These "native interoperability" modes allow switches to operate in the native mode of another vendor and still maintain some of the proprietary behaviors of both. However, running in native interoperability mode may still disable some proprietary features and can produce fabrics of questionable stability. ==Host bus adapters== [[File:QLogic QLE2562 8Gb FC HBA.jpg|thumb|200px|Dual port 8 Gb FC host bus adapter card]] [[File:Qlogic qle2672-ck.jpg|thumb|200px|Dual port 16 Gb FC host bus adapter card]] Fibre Channel [[Host adapter|HBA]]s, as well as [[Converged network adapter|CNA]]s, are available for all major [[Open system (computing)|open systems]], computer architectures, and buses, including [[Peripheral Component Interconnect|PCI]] and [[SBus]]. HBAs connect servers to the Fibre Channel network and are part of a class of devices known as translation devices. Some are OS dependent. Each HBA has a unique [[World Wide Name]] (WWN), which is similar to an Ethernet [[MAC address]] in that it uses an [[Organizationally Unique Identifier]] (OUI) assigned by the [[IEEE]]. However, WWNs are longer (8 [[byte]]s). There are two types of WWNs on an HBA; a [[World Wide Node Name]] (WWNN), which can be shared by some or all ports of a device, and a [[World Wide Port Name]] (WWPN), which is necessarily unique to each port. Adapters or routers can connect Fibre Channel networks to IP or Ethernet networks.<ref>{{cite web | url=https://fibrechannel.org/hardware/ | title=Hardware | date=25 September 2012 }}</ref> ==See also== {{div col|colwidth=25em}} * [[8b/10b encoding]], [[64b/66b encoding]] * [[Fabric Application Interface Standard]] * [[Fibre Channel zoning]] * [[Registered State Change Notification]] * [[vsan|Virtual Storage Area Network]] * [[Fibre Channel frame]] * [[Fibre Channel network protocols]] * [[FCoE|Fibre Channel over Ethernet]] (FCoE) * [[Fibre Channel over IP]] (FCIP), contrast with [[Internet Fibre Channel Protocol]] (iFCP) * [[Gen 5 Fibre Channel]] * [[Host Bus Adapter]] (HBA) * [[Interconnect bottleneck]] * [[FATA (hard drive)|FATA]], [[Integrated Drive Electronics|IDE]], [[Advanced Technology Attachment|ATA]], [[SATA]], [[Serial Attached SCSI|SAS]], [[ATA over Ethernet|AoE]], [[SCSI]], [[iSCSI]], [[PCI Express]] * [[IPFC|IP over Fibre Channel]] (IPFC) * [[NPIV|N_Port ID Virtualization]] * [[World Wide Name]] {{Div col end}} ==References== {{Reflist|30em}} ===INCITS standards=== {{Reflist|group=ITS}} ==Sources== * Clark, T. ''Designing Storage Area Networks'', Addison-Wesley, 1999. {{ISBN|0-201-61584-3}} ==Further reading== * {{IETF RFC|2625}} β IP and ARP over Fibre Channel * {{IETF RFC|2837}} β Definitions of Managed Objects for the Fabric Element in Fibre Channel Standard * {{IETF RFC|3723}} β Securing Block Storage Protocols over IP * {{IETF RFC|4044}} β Fibre Channel Management [[Management information base|MIB]] * {{IETF RFC|4625}} β Fibre Channel Routing Information MIB * {{IETF RFC|4626}} β MIB for Fibre Channel's Fabric Shortest Path First (FSPF) Protocol == External links == <!-- ATTENTION! Please do not add links without discussion and consensus on the talk page. Undiscussed links will be removed. --> * [http://www.fibrechannel.org/ Fibre Channel Industry Association] (FCIA) * [http://www.t11.org/index.html INCITS technical committee responsible for FC standards(T11)] * [http://www.redbooks.ibm.com/redbooks.nsf/0/f98c75e7c6b5a4ca88256d0c0060bcc0?OpenDocument IBM SAN Survival Guide] * [http://www.redbooks.ibm.com/abstracts/sg245470.html?Open Introduction to Storage Area Networks] * [http://hsi.web.cern.ch/HSI/fcs/spec/overview.htm Fibre Channel overview] * [http://www.iol.unh.edu/training/fc/tutorials/fc_tutorial.php Fibre Channel tutorial] (UNH-IOL) * [http://www.snia.org Storage Networking Industry Association] (SNIA) * [http://thetechnologychronicle.blogspot.in/2013/12/virtual-fibre-channel-in-hyper-v.html Virtual fibre Channel in Hyper V] {{Computer-bus}} {{Solid-state drive}} {{Authority control}} [[Category:Fibre Channel| ]] [[Category:Computer storage buses]]
Summary:
Please note that all contributions to Niidae Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
Encyclopedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Templates used on this page:
Template:Authority control
(
edit
)
Template:Cite book
(
edit
)
Template:Cite web
(
edit
)
Template:Computer-bus
(
edit
)
Template:Contradict section
(
edit
)
Template:Div col
(
edit
)
Template:Div col end
(
edit
)
Template:Dunno
(
edit
)
Template:Fibre Channel
(
edit
)
Template:IETF RFC
(
edit
)
Template:ISBN
(
edit
)
Template:Missing information
(
edit
)
Template:Multiple issues
(
edit
)
Template:Mw-datatable
(
edit
)
Template:N/A
(
edit
)
Template:Nowrap
(
edit
)
Template:Reflist
(
edit
)
Template:Short description
(
edit
)
Template:Snd
(
edit
)
Template:Solid-state drive
(
edit
)
Template:Vanchor
(
edit
)
Template:Visible anchor
(
edit
)
Template:Webarchive
(
edit
)
Search
Search
Editing
Fibre Channel
Add topic