Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Special pages
Niidae Wiki
Search
Search
Appearance
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
Glucose tolerance test
(section)
Page
Discussion
English
Read
Edit
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
View history
General
What links here
Related changes
Page information
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
==Sample method== The diagnosis criteria stated above by the World Health Organization (WHO) are for venous samples only (a blood sample taken from a vein in the arm). An increasingly popular method for measuring blood glucose is to sample capillary or finger-prick blood, which is less invasive, more convenient for the patient and requires minimal training to conduct. Though fasting blood glucose levels have been shown to be similar in both capillary and venous samples, postprandial blood glucose levels (those measured after a meal) can vary.<ref name=nevander>{{cite journal | last1=Nevander | first1=Sofia | last2=Landberg | first2=Eva | last3=Blomberg | first3=Marie | last4=Ekman | first4=Bertil | last5=Lilliecreutz | first5=Caroline | title=Comparison of Venous and Capillary Sampling in Oral Glucose Testing for the Diagnosis of Gestational Diabetes Mellitus: A Diagnostic Accuracy Cross-Sectional Study Using Accu-Chek Inform II | journal=Diagnostics| volume=10 | issue=12 | date=26 November 2020 | issn=2075-4418 | doi=10.3390/diagnostics10121011|doi-access=free | page=1011| pmid=33255868 | pmc=7760160 }}</ref> The diagnosis criteria issued by the WHO are only suitable for venous blood samples. Given the increasing popularity of capillary testing, the WHO has recommended that a conversion factor between the two sample types be calculated, but {{As of|2017|lc=y}} no conversion factor had been issued by the WHO, despite some medical professionals adopting their own.{{citation needed|date=November 2021}} A 2020 study on pregnant women for gestational diabetes mellitus (GDM) found that 0-hour venous and capillary levels were similar, but that 2-hour samples were different. The authors compared their study with others, and concluded that capillary samples could be used for diagnosis of GDM during pregnancy using corrected cutoffs with acceptable accuracy in an antenatal care setting.<ref name=nevander/><!--older WHO documents find fairly consistently that capillary values are similar at 0h, and about 1.1mmol/l higher at 2 hours, reasonably consistent with Nevander et al. https://apps.who.int/iris/rest/bitstreams/51753/retrieve (1994). https://applications.emro.who.int/dsaf/dsa509.pdf (2006). This could be added to the article, but should perhaps be discussed first.-->
Summary:
Please note that all contributions to Niidae Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
Encyclopedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Search
Search
Editing
Glucose tolerance test
(section)
Add topic