Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Special pages
Niidae Wiki
Search
Search
Appearance
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
X-ray fluorescence
(section)
Page
Discussion
English
Read
Edit
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
View history
General
What links here
Related changes
Page information
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
==Chemical analysis== The use of a primary X-ray beam to excite fluorescent radiation from the sample was first proposed by [[Richard Glocker|Glocker]] and [[Hans-Wilhelm Schreiber|Schreiber]] in 1928.<ref>Glocker, R., and Schreiber, H., ''Annalen der Physik.'', 85, (1928), p. 1089</ref> Today, the method is used as a non-destructive analytical technique, and as a process control tool in many extractive and processing industries. In principle, the lightest element that can be analysed is [[beryllium]] (Z = 4), but due to instrumental limitations and low X-ray yields for the light elements, it is often difficult to quantify elements lighter than [[sodium]] (Z = 11), unless background corrections and very comprehensive inter-element corrections are made. [[File:dmedxrfschematic.jpg|thumb|Figure 4: Schematic arrangement of EDX spectrometer]] ===Energy dispersive spectrometry=== {{main|Energy-dispersive X-ray spectroscopy}} In [[energy dispersive X-ray spectroscopy|energy-dispersive]] spectrometers (EDX or EDS), the detector allows the determination of the energy of the photon when it is detected. Detectors historically have been based on silicon semiconductors, in the form of lithium-drifted silicon crystals, or high-purity silicon wafers. [[File:DmedxrfSiLiDetector.jpg|thumb|Figure 5: Schematic form of a Si(Li) detector]] ====Si(Li) detectors==== These consist essentially of a 3–5 mm thick silicon junction type p-i-n diode (same as PIN diode) with a bias of −1000 V across it. The lithium-drifted centre part forms the non-conducting i-layer, where Li compensates the residual acceptors which would otherwise make the layer p-type. When an X-ray photon passes through, it causes a swarm of electron-hole pairs to form, and this causes a voltage pulse. To obtain sufficiently low conductivity, the detector must be maintained at low temperature, and liquid-nitrogen cooling must be used for the best resolution. With some loss of resolution, the much more convenient Peltier cooling can be employed.<ref>{{cite book|url=https://books.google.com/books?id=667SJf95AFAC&pg=PA559|page=559|title=Transmission electron microscopy: a textbook for materials science|volume=2|author=David Bernard Williams|author2=C. Barry Carter|publisher=Springer|date=1996|isbn=978-0-306-45324-3}}</ref> ====Wafer detectors==== More recently, high-purity silicon wafers with low conductivity have become routinely available. Cooled by the [[Thermoelectric effect#Peltier effect|Peltier effect]], this provides a cheap and convenient detector, although the [[liquid nitrogen]] cooled Si(Li) detector still has the best resolution (i.e. ability to distinguish different photon energies). ====Amplifiers==== The pulses generated by the detector are processed by [[pulse-shaping]] amplifiers. It takes time for the amplifier to shape the pulse for optimum resolution, and there is therefore a trade-off between resolution and count-rate: long processing time for good resolution results in "pulse pile-up" in which the pulses from successive photons overlap. Multi-photon events are, however, typically more drawn out in time (photons did not arrive exactly at the same time) than single photon events and pulse-length discrimination can thus be used to filter most of these out. Even so, a small number of pile-up peaks will remain and pile-up correction should be built into the software in applications that require trace analysis. To make the most efficient use of the detector, the tube current should be reduced to keep multi-photon events (before discrimination) at a reasonable level, e.g. 5–20%. ====Processing==== Considerable computer power is dedicated to correcting for pulse-pile up and for extraction of data from poorly resolved spectra. These elaborate correction processes tend to be based on empirical relationships that may change with time, so that continuous vigilance is required in order to obtain chemical data of adequate precision. Digital pulse processors are widely used in high performance nuclear instrumentation. They are able to effectively reduce pile-up and base line shifts, allowing for easier processing. A low pass filter is integrated, improving the signal to noise ratio. The Digital Pulse Processor requires a significant amount of energy to run, but it provides precise results. ====Usage==== [[Energy-dispersive X-ray spectroscopy|EDX]] spectrometers are different from [[Wavelength dispersive X-ray spectroscopy|WDX]] spectrometers in that they are smaller, simpler in design and have fewer engineered parts, however the accuracy and resolution of EDX spectrometers are lower than for WDX. EDX spectrometers can also use miniature X-ray tubes or gamma sources, which makes them cheaper and allows miniaturization and portability. This type of instrument is commonly used for portable quality control screening applications, such as testing toys for lead (Pb) content, sorting scrap metals, and measuring the lead content of residential paint. On the other hand, the low resolution and problems with low count rate and long dead-time makes them inferior for high-precision analysis. They are, however, very effective for high-speed, multi-elemental analysis. Field Portable XRF analysers currently on the market weigh less than 2 kg, and have limits of detection on the order of 2 parts per million of lead (Pb) in pure sand. Using a Scanning Electron Microscope and using EDX, studies have been broadened to organic based samples such as biological samples and polymers. [[File:dmwdxrfschematic.jpg|thumb|Figure 6: Schematic arrangement of wavelength dispersive spectrometer]] [[File:XRFgoniometer manual.jpg|thumb|right|Chemist operates a [[goniometer]] used for X-ray fluorescence analysis of individual grains of mineral specimens, [[U.S. Geological Survey]], 1958.]] ===Wavelength dispersive spectrometry=== In wavelength dispersive spectrometers ([[WDX]] or [[Wavelength dispersive X-ray spectroscopy|WDS]]), the photons are separated by [[diffraction]] on a single crystal before being detected. Although wavelength dispersive spectrometers are occasionally used to scan a wide range of wavelengths, producing a spectrum plot as in EDS, they are usually set up to make measurements only at the wavelength of the emission lines of the elements of interest. This is achieved in two different ways: *'''"Simultaneous" spectrometers''' have a number of "channels" dedicated to analysis of a single element, each consisting of a fixed-geometry crystal monochromator, a detector, and processing electronics. This allows a number of elements to be measured simultaneously, and in the case of high-powered instruments, complete high-precision analyses can be obtained in under 30 s. Another advantage of this arrangement is that the fixed-geometry monochromators have no continuously moving parts, and so are very reliable. Reliability is important in production environments where instruments are expected to work without interruption for months at a time. Disadvantages of simultaneous spectrometers include relatively high cost for complex analyses, since each channel used is expensive. The number of elements that can be measured is limited to 15–20, because of space limitations on the number of monochromators that can be crowded around the fluorescing sample. The need to accommodate multiple monochromators means that a rather open arrangement around the sample is required, leading to relatively long tube-sample-crystal distances, which leads to lower detected intensities and more scattering. The instrument is inflexible, because if a new element is to be measured, a new measurement channel has to be bought and installed. *'''"Sequential" spectrometers''' have a single variable-geometry monochromator (but usually with an arrangement for selecting from a choice of crystals), a single detector assembly (but usually with more than one detector arranged in tandem), and a single electronic pack. The instrument is programmed to move through a sequence of wavelengths, in each case selecting the appropriate X-ray tube power, the appropriate crystal, and the appropriate detector arrangement. The length of the measurement program is essentially unlimited, so this arrangement is very flexible. Because there is only one monochromator, the tube-sample-crystal distances can be kept very short, resulting in minimal loss of detected intensity. The obvious disadvantage is relatively long analysis time, particularly when many elements are being analysed, not only because the elements are measured in sequence, but also because a certain amount of time is taken in readjusting the monochromator geometry between measurements. Furthermore, the frenzied activity of the monochromator during an analysis program is a challenge for mechanical reliability. However, modern sequential instruments can achieve reliability almost as good as that of simultaneous instruments, even in continuous-usage applications. ====Sample preparation==== In order to keep the geometry of the tube-sample-detector assembly constant, the sample is normally prepared as a flat disc, typically of diameter 20–50 mm. This is located at a standardized, small distance from the tube window. Because the X-ray intensity follows an inverse-square law, the tolerances for this placement and for the flatness of the surface must be very tight in order to maintain a repeatable X-ray flux. Ways of obtaining sample discs vary: metals may be machined to shape, minerals may be finely ground and pressed into a tablet, and glasses may be cast to the required shape. A further reason for obtaining a flat and representative sample surface is that the secondary X-rays from lighter elements often only emit from the top few micrometres of the sample. In order to further reduce the effect of surface irregularities, the sample is usually spun at 5–20 rpm. It is necessary to ensure that the sample is sufficiently thick to absorb the entire primary beam. For higher-Z materials, a few millimetres thickness is adequate, but for a light-element matrix such as coal, a thickness of 30–40 mm is needed. [[File:dmbraggreflection.jpg|thumb|Figure 7: Bragg diffraction condition]] ====Monochromators==== The common feature of monochromators is the maintenance of a symmetrical geometry between the sample, the crystal and the detector. In this geometry the Bragg diffraction condition is obtained. The X-ray emission lines are very narrow (see figure 2), so the angles must be defined with considerable precision. This is achieved in two ways: =====Flat crystal with Söller collimators===== A [[Collimator#X-ray, gamma ray, and neutron collimators|Söller collimator]] is a stack of parallel metal plates, spaced a few tenths of a millimeter apart. To improve angular resolution, one must lengthen the collimator, and/or reduce the plate spacing. This arrangement has the advantage of simplicity and relatively low cost, but the collimators reduce intensity and increase scattering, and reduce the area of sample and crystal that can be "seen". The simplicity of the geometry is especially useful for variable-geometry monochromators. [[File:dmwdxrfFlatXtalMonochrom.jpg|thumb|Figure 8: Flat crystal with Soller collimators]] [[File:dmwdxrfCurvedXtalMonochrom.jpg|thumb|Figure 9: Curved crystal with slits]] =====Curved crystal with slits===== The Rowland circle geometry ensures that the slits are both in focus, but in order for the Bragg condition to be met at all points, the crystal must first be bent to a radius of 2R (where R is the radius of the Rowland circle), then ground to a radius of R. This arrangement allows higher intensities (typically 8-fold) with higher resolution (typically 4-fold) and lower background. However, the mechanics of keeping Rowland circle geometry in a variable-angle monochromator is extremely difficult. In the case of fixed-angle monochromators (for use in simultaneous spectrometers), crystals bent to a logarithmic spiral shape give the best focusing performance. The manufacture of curved crystals to acceptable tolerances increases their price considerably. ====Crystal materials==== An intuitive understanding of X-ray diffraction can be obtained from the [[Bragg diffraction|Bragg model of diffraction]]. In this model, a given reflection is associated with a set of evenly spaced sheets running through the crystal, usually passing through the centers of the atoms of the crystal lattice. The orientation of a particular set of sheets is identified by its [[Miller index|three Miller indices]] (''h'', ''k'', ''l''), and let their spacing be noted by ''d''. William Lawrence Bragg proposed a model in which the incoming X-rays are scattered specularly (mirror-like) from each plane; from that assumption, X-rays scattered from adjacent planes will combine constructively ([[constructive interference]]) when the angle {{mvar|θ}} between the plane and the X-ray results in a path-length difference that is an integer multiple ''n'' of the X-ray wavelength λ.(Fig.7) : <math>2 d\sin\theta = n\lambda.</math> <!--copied content from [[:X-ray crystallography]]; see that page's history for attribution--> The desirable characteristics of a diffraction crystal are:{{citation needed|date=July 2020}} *High diffraction intensity *High dispersion *Narrow diffracted peak width *High peak-to-background *Absence of interfering elements *Low thermal coefficient of expansion *Stability in air and on exposure to X-rays *Ready availability *Low cost Crystals with simple structures tend to give the best diffraction performance. Crystals containing heavy atoms can diffract well, but also fluoresce more in the higher energy region, causing interference. Crystals that are water-soluble, volatile or organic tend to give poor stability. Commonly used crystal materials include LiF ([[lithium fluoride]]), ADP ([[ammonium dihydrogen phosphate]]), Ge ([[germanium]]), Si ([[silicon]]), [[graphite]], InSb ([[indium antimonide]]), PE (''tetrakis''-(hydroxymethyl)-methane, also known as [[pentaerythritol]]), KAP ([[potassium hydrogen phthalate]]), RbAP (rubidium hydrogen phthalate) and TlAP (thallium(I) hydrogen phthalate). In addition, there is an increasing use of "layered synthetic microstructures" (LSMs), which are "sandwich" structured materials comprising successive thick layers of low atomic number matrix, and monatomic layers of a heavy element. These can in principle be custom-manufactured to diffract any desired long wavelength, and are used extensively for elements in the range Li to Mg. In scientific methods that use X-ray/neutron or electron diffraction the before mentioned planes of a diffraction can be doubled to display higher order reflections. The given planes, resulting from Miller indices, can be calculated for a single crystal. The resulting values for ''h, k and l'' are then called [[Laue equations|Laue indices]]. So a single crystal can be variable in the way, that many reflection configurations of that crystal can be used to reflect different energy ranges. The Germanium (Ge111) crystal, for example, can also be used as a Ge333, Ge444 and more. For that reason the corresponding indices used for a particular experimental setup always get noted behind the crystal material(e.g. Ge111, Ge444) Notice, that the Ge222 configuration is forbidden due to diffraction rules stating, that all allowed reflections must be with all odd or all even Miller indices that, combined, result in <math>4n</math>, where <math>n</math> is the order of reflection. {| class="wikitable" |+ Properties of commonly used crystals |- !width="100"|material !width="80"|[[Miller index|plane]] !width="80"|d (nm) !width="80"|min λ (nm) !width="80"|max λ (nm) !width="80"|intensity !width="80"|thermal expansion !width="80"|durability |- |[[LiF]]||200||0.2014||0.053||0.379||+++++||+++||+++ |- |LiF||220||0.1424||0.037||0.268||+++||++||+++ |- |LiF||420||0.0901||0.024||0.169||++||++||+++ |- |[[Ammonium dihydrogen phosphate|ADP]]||101||0.5320||0.139||1.000||+||++||++ |- |[[Germanium|Ge]]||111||0.3266||0.085||0.614||+++||+||+++ |- |Ge||222||0,1633||forbidden||forbidden||+++||+||+++ |- |Ge||333||0,1088||0,17839||0,21752||+++||+||+++ |- |Ge||444||0,0816||0,13625||0,16314||+++||+||+++ |- |Ge||310||0,1789||forbidden||forbidden||+++||+||+++ |- |Ge||620||0,0894||0,14673||0,17839||+++||+||+++ |- |[[Graphite]]||001||0.3354||0.088||0.630||++++||+||+++ |- |[[InSb]]||111||0.3740||0.098||0.703||++++||+||+++ |- |[[Pentaerythritol|PE]]||002||0.4371||0.114||0.821||+++||+++++||+ |- |[[Potassium hydrogen phthalate|KAP]]||1010||1.325||0.346||2.490||++||++||++ |- |[[RbAP]]||1010||1.305||0.341||2.453||++||++||++ |- |[[Silicon|Si]]||111||0.3135||0.082||0.589||++||+||+++ |- |[[TlAP]]||1010||1.295||0.338||2.434||+++||++||++ |- |[[Yttrium borides#YB66|YB<sub>66</sub>]]||400||0.586|| || || || || |- |6 nm LSM||-||6.00||1.566||11.276||+++||+||++ |} ====Elemental analysis lines==== The spectral lines used for elemental analysis of chemicals are selected on the basis of intensity, accessibility by the instrument, and lack of line overlaps. Typical lines used, and their wavelengths, are as follows: {| class="wikitable" !element!![[Siegbahn notation|line]] !!wavelength (nm) !! !!element !!line !!wavelength (nm) !! !!element !!line !!wavelength (nm) !! !!element !!line !!wavelength (nm) |- |Li||Kα||22.8|| ||Ni||Kα<sub>1</sub>||0.1658|| ||I||Lα<sub>1</sub>||0.3149|| ||Pt||Lα<sub>1</sub>||0.1313 |- |Be||Kα||11.4|| ||Cu||Kα<sub>1</sub>||0.1541|| ||Xe||Lα<sub>1</sub>||0.3016|| ||Au||Lα<sub>1</sub>||0.1276 |- |B||Kα||6.76|| ||Zn||Kα<sub>1</sub>||0.1435|| ||Cs||Lα<sub>1</sub>||0.2892|| ||Hg||Lα<sub>1</sub>||0.1241 |- |C||Kα||4.47|| ||Ga||Kα<sub>1</sub>||0.1340|| ||Ba||Lα<sub>1</sub>||0.2776|| ||Tl||Lα<sub>1</sub>||0.1207 |- |N||Kα||3.16|| ||Ge||Kα<sub>1</sub>||0.1254|| ||La||Lα<sub>1</sub>||0.2666|| ||Pb||Lα<sub>1</sub>||0.1175 |- |O||Kα||2.362|| ||As||Kα<sub>1</sub>||0.1176|| ||Ce||Lα<sub>1</sub>||0.2562|| ||Bi||Lα<sub>1</sub>||0.1144 |- |F||Kα<sub>1,2</sub>||1.832|| ||Se||Kα<sub>1</sub>||0.1105|| ||Pr||Lα<sub>1</sub>||0.2463|| ||Po||Lα<sub>1</sub>||0.1114 |- |Ne||Kα<sub>1,2</sub>||1.461|| ||Br||Kα<sub>1</sub>||0.1040|| ||Nd||Lα<sub>1</sub>||0.2370|| ||At||Lα<sub>1</sub>||0.1085 |- |Na||Kα<sub>1,2</sub>||1.191|| ||Kr||Kα<sub>1</sub>||0.09801|| ||Pm||Lα<sub>1</sub>||0.2282|| ||Rn||Lα<sub>1</sub>||0.1057 |- |Mg||Kα<sub>1,2</sub>||0.989|| ||Rb||Kα<sub>1</sub>||0.09256|| ||Sm||Lα<sub>1</sub>||0.2200|| ||Fr||Lα<sub>1</sub>||0.1031 |- |Al||Kα<sub>1,2</sub>||0.834|| ||Sr||Kα<sub>1</sub>||0.08753|| ||Eu||Lα<sub>1</sub>||0.2121|| ||Ra||Lα<sub>1</sub>||0.1005 |- |Si||Kα<sub>1,2</sub>||0.7126|| ||Y||Kα<sub>1</sub>||0.08288|| ||Gd||Lα<sub>1</sub>||0.2047|| ||Ac||Lα<sub>1</sub>||0.0980 |- |P||Kα<sub>1,2</sub>||0.6158|| ||Zr||Kα<sub>1</sub>||0.07859|| ||Tb||Lα<sub>1</sub>||0.1977|| ||Th||Lα<sub>1</sub>||0.0956 |- |S||Kα<sub>1,2</sub>||0.5373|| ||Nb||Kα<sub>1</sub>||0.07462|| ||Dy||Lα<sub>1</sub>||0.1909|| ||Pa||Lα<sub>1</sub>||0.0933 |- |Cl||Kα<sub>1,2</sub>||0.4729|| ||Mo||Kα<sub>1</sub>||0.07094|| ||Ho||Lα<sub>1</sub>||0.1845|| ||U||Lα<sub>1</sub>||0.0911 |- |Ar||Kα<sub>1,2</sub>||0.4193|| ||Tc||Kα<sub>1</sub>||0.06751|| ||Er||Lα<sub>1</sub>||0.1784|| ||Np||Lα<sub>1</sub>||0.0888 |- |K||Kα<sub>1,2</sub>||0.3742|| ||Ru||Kα<sub>1</sub>||0.06433|| ||Tm||Lα<sub>1</sub>||0.1727|| ||Pu||Lα<sub>1</sub>||0.0868 |- |Ca||Kα<sub>1,2</sub>||0.3359|| ||Rh||Kα<sub>1</sub>||0.06136|| ||Yb||Lα<sub>1</sub>||0.1672|| ||Am||Lα<sub>1</sub>||0.0847 |- |Sc||Kα<sub>1,2</sub>||0.3032|| ||Pd||Kα<sub>1</sub>||0.05859|| ||Lu||Lα<sub>1</sub>||0.1620|| ||Cm||Lα<sub>1</sub>||0.0828 |- |Ti||Kα<sub>1,2</sub>||0.2749|| ||Ag||Kα<sub>1</sub>||0.05599|| ||Hf||Lα<sub>1</sub>||0.1570|| ||Bk||Lα<sub>1</sub>||0.0809 |- |V||Kα<sub>1</sub>||0.2504|| ||Cd||Kα<sub>1</sub>||0.05357|| ||Ta||Lα<sub>1</sub>||0.1522|| ||Cf||Lα<sub>1</sub>||0.0791 |- |Cr||Kα<sub>1</sub>||0.2290|| ||In||Lα<sub>1</sub>||0.3772|| ||W||Lα<sub>1</sub>||0.1476|| ||Es||Lα<sub>1</sub>||0.0773 |- |Mn||Kα<sub>1</sub>||0.2102|| ||Sn||Lα<sub>1</sub>||0.3600|| ||Re||Lα<sub>1</sub>||0.1433|| ||Fm||Lα<sub>1</sub>||0.0756 |- |Fe||Kα<sub>1</sub>||0.1936|| ||Sb||Lα<sub>1</sub>||0.3439|| ||Os||Lα<sub>1</sub>||0.1391|| ||Md||Lα<sub>1</sub>||0.0740 |- |Co||Kα<sub>1</sub>||0.1789|| ||Te||Lα<sub>1</sub>||0.3289|| ||Ir||Lα<sub>1</sub>||0.1351|| ||No||Lα<sub>1</sub>||0.0724 |- |} Other lines are often used, depending on the type of sample and equipment available. ====Structural analysis lines==== [[File:K-Beta & VtC.PNG|thumb|right|250px| Figure 10:K-Beta Mainline and V2C]] X-ray diffraction (XRD) is still the most used method for structural analysis of chemical compounds. Yet, with increasing detail on the relation of <math>K_{\beta}</math>-line spectra and the surrounding chemical environment of the ionized metal atom, measurements of the so-called valence-to-core (V2C) energy region become increasingly viable. Scientists noted that after ionization of 3d-transition metal atom, the <math>K_{\beta}</math>-line intensities and energies shift with oxidation state of the metal and with the species of ligand(s). Spin states in a compound tend to affect this kind of measurement.<ref>S. DeBeer: [http://sites.psu.edu/bioinorganic/wp-content/uploads/sites/29389/2015/08/2016-04-DeBeer-advanced-x-ray-spectroscopy.pdf ''Advanced X-Ray Spectroscopy''] (PDF) June 2016, last checked 20.07.2020</ref> This means, that by intense study of these spectral lines, one can obtain several crucial pieces of information from a sample. Especially, if there are references that have been studied in detail and can be used to make out differences. The information collected from this kind of measurement include: *Oxidation state of the central metal atom in a compound (shifts of <math>K_{\beta1,3}</math>-mainline in low-spin complexes) *Spin states of transition metal complexes (general shape of <math>K_{\beta1,3}</math>- and <math>K_{\beta'}</math>-mainlines) *Structural electronic configuration around the central metal atom (determine intensity, broadening, tailing and piloting of <math>K_{\beta2,5}</math>- and <math>K_{\beta''}</math>-lines) These measurements are mostly done at [[synchrotron]] facilities, although a number of so-called "in-lab"-spectrometers have been developed and used for pre-beamtime (time at a synchrotron) measurements.<ref>D.Sokaras: [https://www.researchgate.net/publication/237068866_A_seven-crystal_Johann-type_hard_x-ray_spectrometer_at_the_Stanford_Synchrotron_Radiation_Lightsource ''A seven-crystal Johann-type hard x-ray spectrometer at the Stanford Synchrotron Radiation Lightsource ''] 2013, last checked 20.07.2020</ref><ref>D.B. Wittry: [http://www.geoscience.wisc.edu/~johnf/g777/MM/Wittry.pdf ''X-ray Crystal Spectrometers and Monochromators in Microanalysis''] 2001, last checked 20.07.2020</ref> ====Detectors==== Detectors used for wavelength dispersive spectrometry need to have high pulse processing speeds in order to cope with the very high photon count rates that can be obtained. In addition, they need sufficient energy resolution to allow filtering-out of background noise and spurious photons from the primary beam or from crystal fluorescence. There are four common types of detector: *gas flow proportional counters *sealed gas detectors *scintillation counters *semiconductor detectors [[File:dmwdxrfFlowDetector.jpg|thumb|Figure 11: Arrangement of gas flow proportional counter]] '''Gas flow proportional counters''' are used mainly for detection of longer wavelengths. Gas flows through it continuously. Where there are multiple detectors, the gas is passed through them in series, then led to waste. The gas is usually 90% argon, 10% methane ("P10"), although the argon may be replaced with neon or helium where very long wavelengths (over 5 nm) are to be detected. The argon is ionised by incoming X-ray photons, and the electric field multiplies this charge into a measurable pulse. The methane suppresses the formation of fluorescent photons caused by recombination of the argon ions with stray electrons. The anode wire is typically tungsten or nichrome of 20–60 μm diameter. Since the pulse strength obtained is essentially proportional to the ratio of the detector chamber diameter to the wire diameter, a fine wire is needed, but it must also be strong enough to be maintained under tension so that it remains precisely straight and concentric with the detector. The window needs to be conductive, thin enough to transmit the X-rays effectively, but thick and strong enough to minimize diffusion of the detector gas into the high vacuum of the monochromator chamber. Materials often used are beryllium metal, [[Metallized polyethylene terephthalate|aluminised PET film]] and aluminised [[polypropylene]]. Ultra-thin windows (down to 1 μm) for use with low-penetration long wavelengths are very expensive. The pulses are sorted electronically by "pulse height selection" in order to isolate those pulses deriving from the secondary X-ray photons being counted. '''Sealed gas detectors''' are similar to the gas flow proportional counter, except that the gas does not flow through it. The gas is usually krypton or xenon at a few atmospheres pressure. They are applied usually to wavelengths in the 0.15–0.6 nm range. They are applicable in principle to longer wavelengths, but are limited by the problem of manufacturing a thin window capable of withstanding the high pressure difference. '''Scintillation counters''' consist of a scintillating crystal (typically of sodium iodide doped with thallium) attached to a photomultiplier. The crystal produces a group of scintillations for each photon absorbed, the number being proportional to the photon energy. This translates into a pulse from the photomultiplier of voltage proportional to the photon energy. The crystal must be protected with a relatively thick aluminium/beryllium foil window, which limits the use of the detector to wavelengths below 0.25 nm. Scintillation counters are often connected in series with a gas flow proportional counter: the latter is provided with an outlet window opposite the inlet, to which the scintillation counter is attached. This arrangement is particularly used in sequential spectrometers. '''Semiconductor detectors''' can be used in theory, and their applications are increasing as their technology improves, but historically their use for WDX has been restricted by their slow response (see EDX). [[File:LDHerzogBeadMaking.jpg|thumb|A glass "bead" specimen for XRF analysis being cast at around 1100 °C in a Herzog automated fusion machine in a cement plant quality control laboratory. 1 (top): fusing, 2: preheating the mould, 3: pouring the melt, 4: cooling the "bead"]] ====Extracting analytical results==== At first sight, the translation of X-ray photon count-rates into elemental concentrations would appear to be straightforward: WDX separates the X-ray lines efficiently, and the rate of ''generation'' of secondary photons is proportional to the element concentration. However, the number of photons ''leaving the sample'' is also affected by the physical properties of the sample: so-called "[[matrix effects]]". These fall broadly into three categories: *X-ray absorption *X-ray enhancement *sample macroscopic effects All elements ''absorb'' X-rays to some extent. Each element has a characteristic absorption spectrum which consists of a "saw-tooth" succession of fringes, each step-change of which has wavelength close to an emission line of the element. Absorption attenuates the secondary X-rays leaving the sample. For example, the mass absorption coefficient of silicon at the wavelength of the aluminium Kα line is 50 m<sup>2</sup>/kg, whereas that of iron is 377 m<sup>2</sup>/kg. This means that fluorescent X-rays generated by a given concentration of aluminium in a matrix of iron are absorbed about seven times more (that is 377/50) compared with the fluorescent X-rays generated by the same concentration of aluminium, but in a silicon matrix. That would lead to about one seventh of the count rate, once the X-rays are detected. Fortunately, mass absorption coefficients are well known and can be calculated. However, to calculate the absorption for a multi-element sample, the composition must be known. For analysis of an unknown sample, an iterative procedure is therefore used. To derive the mass absorption accurately, data for the concentration of elements not measured by XRF may be needed, and various strategies are employed to estimate these. As an example, in cement analysis, the concentration of oxygen (which is not measured) is calculated by assuming that all other elements are present as standard oxides. '''Enhancement''' occurs where the secondary X-rays emitted by a heavier element are sufficiently energetic to stimulate additional secondary emission from a lighter element. This phenomenon can also be modelled, and corrections can be made provided that the full matrix composition can be deduced. '''Sample macroscopic effects''' consist of effects of inhomogeneities of the sample, and unrepresentative conditions at its surface. Samples are ideally homogeneous and isotropic, but they often deviate from this ideal. Mixtures of multiple crystalline components in mineral powders can result in absorption effects that deviate from those calculable from theory. When a powder is pressed into a tablet, the finer minerals concentrate at the surface. Spherical grains tend to migrate to the surface more than do angular grains. In machined metals, the softer components of an alloy tend to smear across the surface. Considerable care and ingenuity are required to minimize these effects. Because they are artifacts of the method of sample preparation, these effects can not be compensated by theoretical corrections, and must be "calibrated in". This means that the calibration materials and the unknowns must be compositionally and mechanically similar, and a given calibration is applicable only to a limited range of materials. Glasses most closely approach the ideal of homogeneity and isotropy, and for accurate work, minerals are usually prepared by dissolving them in a borate glass, and casting them into a flat disc or "bead". Prepared in this form, a virtually universal calibration is applicable. Further corrections that are often employed include background correction and line overlap correction. The background signal in an XRF spectrum derives primarily from scattering of primary beam photons by the sample surface. Scattering varies with the sample mass absorption, being greatest when mean atomic number is low. When measuring trace amounts of an element, or when measuring on a variable light matrix, background correction becomes necessary. This is really only feasible on a sequential spectrometer. Line overlap is a common problem, bearing in mind that the spectrum of a complex mineral can contain several hundred measurable lines. Sometimes it can be overcome by measuring a less-intense, but overlap-free line, but in certain instances a correction is inevitable. For instance, the Kα is the only usable line for measuring sodium, and it overlaps the zinc Lβ (L<sub>2</sub>-M<sub>4</sub>) line. Thus zinc, if present, must be analysed in order to properly correct the sodium value.
Summary:
Please note that all contributions to Niidae Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
Encyclopedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Search
Search
Editing
X-ray fluorescence
(section)
Add topic