Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Special pages
Niidae Wiki
Search
Search
Appearance
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
Mariner 2
(section)
Page
Discussion
English
Read
Edit
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
View history
General
What links here
Related changes
Page information
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
==== Instruments ==== * A two-channel '''[[microwave radiometer]]''' of the crystal video type operating in the standard [[Robert H. Dicke|Dicke]] mode of chopping between the main antenna, pointed at the target, and a reference horn pointed at cold space.{{r|nasa9}} It was used to determine the absolute temperature of Venus' surface and details concerning its atmosphere through its microwave-radiation characteristics, including the daylight and dark hemispheres, and in the region of the terminator. Measurements were performed simultaneously in two frequency bands of 13.5 mm and 19 mm.{{r|report}}{{rp|198–204}}{{r|Barath_Feb64}} The total weight of the radiometer was {{convert|22|lb|kg|-1|order=flip}}. Its average power consumption was 4 watts and its peak power consumption 9 watts.{{r|Barath_Mar63}} [[File:Mariner 2 infrared radiometer.png|thumb|Labeled diagram of the infrared radiometer design]] * A two-channel '''[[infrared]] [[radiometer]]''' to measure the effective temperatures of small areas of Venus. The radiation that was received could originate from the planetary surface, clouds in the atmosphere, the atmosphere itself or a combination of these. The radiation was received in two spectral ranges: 8 to 9 μm (focused on 8.4 μm) and 10 to 10.8 μm (focused on 10.4 μm).{{r|report}}{{rp|205–213}} The latter corresponding to the [[carbon dioxide]] band.{{r|Chase_Mar63}} The total weight of the infrared radiometer, which was housed in a magnesium casting, was {{cvt|1.3|kg|lb}}, and it required 2.4 watts of power. It was designed to measure radiation temperatures between approximately {{convert|200|and|500|K|C F}}.{{r|Chase_Nov63}} * A three-axis '''[[Magnetometer#Fluxgate magnetometer|fluxgate magnetometer]]''' to measure planetary and interplanetary magnetic fields.{{r|report}}{{rp|213–218}} Three probes were incorporated in its sensors, so it could obtain three mutually orthogonal components of the field vector. Readings of these components were separated by 1.9 seconds. It had three analog outputs that had each two sensitivity scales: ± 64 γ and ± 320 γ (1 γ = 1 [[Tesla (unit)|nanotesla]]). These scales were automatically switched by the instrument. The field that the magnetometer observed was the super-position of a nearly constant spacecraft field and the interplanetary field. Thus, it effectively measured only the changes in the interplanetary field.{{r|Coleman}} * An '''[[ionization chamber]]''' with matched '''[[Geiger-Müller tube]]s''' (also known as a [[cosmic ray]] detector) to measure high-energy cosmic radiation.{{r|report}}{{rp|218–219}}{{r|Anderson}} * A '''particle detector''' (implemented through use of an Anton type 213 Geiger-Müller tube) to measure lower radiation (especially near Venus),{{r|report}}{{rp|219–223}}{{r|VanAllen_Frank}} also known as the Iowa detector, as it was provided by the [[University of Iowa]].{{r|Anderson}} It was a miniature tube having a 1.2 mg/cm<sup>2</sup> mica window about {{cvt|0.3|cm|in}} in diameter and weighing about {{cvt|60|g|oz}}. It detected soft [[x-ray]]s efficiently and [[ultraviolet]] inefficiently, and was previously used in [[Injun (satellite)|Injun 1]], [[Explorer 12]] and [[Explorer 14]].{{r|VanAllen_Frank}} It was able to detect protons above 500 keV in energy and electrons above 35 keV.{{r|nasa2}} The length of the basic telemetry frame was 887.04 seconds. During each frame, the counting rate of the detector was sampled twice at intervals separated by 37 seconds. The first sampling was the number of counts during an interval of 9.60 seconds (known as the 'long gate'); the second was the number of counts during an interval of 0.827 seconds (known as the 'short gate'). The long gate accumulator overflowed on the 256th count and the short gate accumulator overflowed on the 65,536th count. The maximum counting rate of the tube was 50,000 per second.{{r|VanAllen_Frank}} * A '''[[cosmic dust]] detector''' to measure the flux of cosmic dust particles in space.{{r|report}}{{rp|223–224}} [[File:Mariner 2 plasma probe.png|thumb|Instrument for studying plasma]] * A '''solar plasma [[spectrometer]]''' to measure the spectrum of low-energy positively charged particles from the Sun, i.e. the [[solar wind]].{{r|report}}{{rp|224–228}} The magnetometer was attached to the top of the mast below the [[omnidirectional antenna]]. Particle detectors were mounted halfway up the mast, along with the cosmic ray detector. The cosmic dust detector and solar plasma spectrometer were attached to the top edges of the spacecraft base. The microwave radiometer, the infrared radiometer and the radiometer reference horns were rigidly mounted to a {{cvt|48|cm|in}} diameter parabolic radiometer antenna mounted near the bottom of the mast. All instruments were operated throughout the cruise and encounter modes except the radiometers, which were only used in the immediate vicinity of Venus. In addition to these scientific instruments, Mariner 2 had a data conditioning system (DCS) and a scientific power switching (SPS) unit. The DCS was a solid-state electronic system designed to gather information from the scientific instruments on board the spacecraft. It had four basic functions: analog-to-digital conversion, digital-to-digital conversion, sampling and instrument-calibration timing, and planetary acquisition. The SPS unit was designed to perform the following three functions: control of the application of [[alternating current|AC]] power to appropriate portions of the science subsystem, application of power to the radiometers and removal of power from the cruise experiments during radiometer calibration periods, and control of the speed and direction of the radiometer scans. The DCS sent signals to the SPS unit to perform the latter two functions.{{r|report}} Not included on any of the Mariner R spacecraft was a camera for visual photos. With payload space at a premium, project scientists considered a camera an unneeded luxury, unable to return useful scientific results. [[Carl Sagan]], one of the Mariner R scientists, unsuccessfully fought for their inclusion, noting that not only might there be breaks in Venus' cloud layer, but "that cameras could also answer questions that we were way too dumb to even pose".{{r|space.com1}}
Summary:
Please note that all contributions to Niidae Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
Encyclopedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Search
Search
Editing
Mariner 2
(section)
Add topic