Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Special pages
Niidae Wiki
Search
Search
Appearance
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
Electrocardiography
(section)
Page
Discussion
English
Read
Edit
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
View history
General
What links here
Related changes
Page information
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
=== 12-Lead ECG === Leads are broken down into three types: limb; augmented limb; and precordial or chest. The 12-lead ECG has a total of three ''limb leads'' and three ''augmented limb leads'' arranged like spokes of a wheel in the [[coronal plane]] (vertical), and six ''precordial leads'' or ''chest leads'' that lie on the perpendicular [[transverse plane]] (horizontal).<ref name="EKGInterp">{{Cite web |url=https://www.nurseslearning.com/courses/nrp/nrp1619/Section%205/index.htm |title=EKG Interpretation |website=Nurses Learning Network |access-date=2019-05-27}}</ref> Electrodes should be placed in standard positions, with 'left' or 'right' referring to [[anatomical]] directions, being the patient's left or right. Exceptions due to emergency or other issues should be recorded to avoid erroneous analysis.<ref>{{cite journal |last1=Jowett |first1=N I |last2=Turner |first2=A M |last3=Cole |first3=A |last4=Jones |first4=P A |title=Modified electrode placement must be recorded when performing 12-lead electrocardiograms |journal=Postgraduate Medical Journal |date=February 2005 |volume=81 |issue=952 |pages=122β125 |doi=10.1136/pgmj.2004.021204 |pmid=15701746 |pmc=1743200 }}</ref> The 12 standard ECG leads and electrodes are listed below.<ref>{{Cite journal |last1=Drew |first1=Barbara J. |last2=Califf |first2=Robert M. |last3=Funk |first3=Marjorie |last4=Kaufman |first4=Elizabeth S. |last5=Krucoff |first5=Mitchell W. |last6=Laks |first6=Michael M. |last7=Macfarlane |first7=Peter W. |last8=Sommargren |first8=Claire |last9=Swiryn |first9=Steven |last10=Van Hare |first10=George F. |date=2004-10-26 |title=Practice Standards for Electrocardiographic Monitoring in Hospital Settings: An American Heart Association Scientific Statement From the Councils on Cardiovascular Nursing, Clinical Cardiology, and Cardiovascular Disease in the Young: Endorsed by the International Society of Computerized Electrocardiology and the American Association of Critical-Care Nurses |url=https://www.ahajournals.org/doi/10.1161/01.CIR.0000145144.56673.59 |journal=Circulation |language=en |volume=110 |issue=17 |pages=2721β2746 |doi=10.1161/01.CIR.0000145144.56673.59 |pmid=15505110 |issn=0009-7322}}</ref> All leads are effectively bipolar, with one positive and one negative electrode; the term "unipolar" is not true, nor useful.<ref name="AHA_ECG_pt1" /> {| class="wikitable collapsible" |+ ECG Electrodes and positioning |- ! Type ! Name ([[American Heart Association|AHA]]) ! Color ([[American Heart Association|AHA]]) ! Placement ! Name ([[International Electrotechnical Commission|IEC]]) ! Color ([[International Electrotechnical Commission|IEC]]) |- ! scope=rowgroup rowspan=4 | Limb | RA (Right Arm) | White | On the right arm, below the shoulders, avoiding thick [[muscle]]. | R (Right) | Red |- | LA (Left Arm) | Black | Symmetrical to the placement of the RA. | L (Left) | Yellow |- | RL (Right Leg) | Green | On the right leg, below the hips. | N (Neutral) | Black |- | LL (Left Leg) | Red | Symmetrical to the placement of the RL. | F (Foot) | Green |- ! scope=rowgroup rowspan=6 | Precordial | V1 | Brown & Red | Fourth [[intercostal space]] on the right [[sternal]] border. | C1 | White & Red |- | V2 | Brown & Yellow | Fourth intercostal space on the left sternal border (symmetrical to V1). | C2 | White & Yellow |- | V3 | Brown & Green | Halfway between electrodes V2 and V4 (in a straight line). | C3 | White & Green |- | V4 | Brown & Blue | Fifth intercostal space on the [[midclavicular line]]. | C4 | White & Brown |- | V5 | Brown & Orange | Left [[anterior axillary line]] on the same horizontal plane as V4. If the anterior axillary line is ambiguous, place halfway between V4 and V6. | C5 | White & Black |- | V6 | Brown & Purple | Left [[midaxillary line]] on the same horizontal plane as V4. | C6 | White & Purple. |} {| class="wikitable collapsible" |+ ECG Leads and Views |- ! Type ! Name ! Lead view |- ! rowspan=3 | Limb | I | From the RA to the LA. Along the frontal and horizontal planes at 0Β° (directly to the left). |- | II | From the RA to the LL. Along the frontal plane at 60Β° clockwise from I. |- | III | From the LA to the LL. Along the frontal plane at 120Β° clockwise from I. |- ! rowspan=3 | Augmented Limb | aVL | From WCT to the LA. Along the frontal plane at -30Β° (which is 330Β° clockwise from I). |- | aVR | From WCT to the RA. Along the frontal plane at -150Β° (which is 210Β° from I). |- | aVF | From WCT to the LL. Along the front plane at 90Β°. |- ! rowspan=6 | Precordial | V<sub>1</sub> | In the fourth [[intercostal space]] (between ribs 4 and 5) just to the right of the [[sternum]] (breastbone) |- | V<sub>2</sub> | In the fourth intercostal space (between ribs 4 and 5) just to the left of the sternum. |- | V<sub>3</sub> | Between leads V<sub>2</sub> and V<sub>4</sub>. |- | V<sub>4</sub> | In the fifth intercostal space (between ribs 5 and 6) in the [[mid-clavicular line]]. |- | V<sub>5</sub> | Along the same horizontal line as V<sub>4</sub>, in the left [[anterior axillary line]]. |- | V<sub>6</sub> | Along the same horizontal line as V<sub>4</sub> and V<sub>5</sub> in the [[midaxillary line|mid-axillary line]]. |} Two types of electrodes in common use are a flat paper-thin sticker and a self-adhesive circular pad. The former are typically used in a single ECG recording while the latter are for continuous recordings as they stick longer. Each electrode consists of an [[electrically conductive]] electrolyte gel and a [[Silver chloride electrode#Biological electrode systems|silver/silver chloride]] conductor.<ref>{{cite book |doi=10.1007/978-1-4613-2323-5_15 |chapter=Advances in Body Surface Potential Mapping (BSPM) Instrumentation |title=Pediatric and Fundamental Electrocardiography |series=Developments in Cardiovascular Medicine |date=1987 |last1=Kavuru |first1=Madhav S. |last2=Vesselle |first2=Hubert |last3=Thomas |first3=Cecil W. |volume=56 |pages=315β327 |isbn=978-1-4612-9428-3 }}</ref> The gel typically contains [[potassium chloride]] β sometimes [[silver chloride]] as well β to permit [[electron]] conduction from the skin to the wire and to the electrocardiogram.<ref>{{cite journal |last1=Tsukada |first1=Yayoi Tetsuou |last2=Tokita |first2=Miwa |last3=Murata |first3=Hiroshige |last4=Hirasawa |first4=Yasuhiro |last5=Yodogawa |first5=Kenji |last6=Iwasaki |first6=Yu-ki |last7=Asai |first7=Kuniya |last8=Shimizu |first8=Wataru |last9=Kasai |first9=Nahoko |last10=Nakashima |first10=Hiroshi |last11=Tsukada |first11=Shingo |title=Validation of wearable textile electrodes for ECG monitoring |journal=Heart and Vessels |date=July 2019 |volume=34 |issue=7 |pages=1203β1211 |doi=10.1007/s00380-019-01347-8 |pmid=30680493 |pmc=6556171 }}</ref>
Summary:
Please note that all contributions to Niidae Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
Encyclopedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Search
Search
Editing
Electrocardiography
(section)
Add topic