Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Special pages
Niidae Wiki
Search
Search
Appearance
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
IBM 3270
(section)
Page
Discussion
English
Read
Edit
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
View history
General
What links here
Related changes
Page information
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
====Commands==== The following table includes datastream commands and CCW opcodes for local non-SNA controllers; it does not include CCW opcodes for local SNA controllers. <!-- Add page number for each command from 3270 Data Stream 0r 3274 Description. --> {| class="wikitable" |+3270 commands{{sfn|3274 Description|loc=Figure 1-8. Command Codes|p=1-14}} ! scope="col" | Command ! scope="col" colspan=3 | Hexadecimal ! scope="col" |Graphic ! scope="col" | Function |- ! scope="col" | ! scope="col" | local<br />non-SNA ! scope="col" | EBCDIC ! scope="col" | ASCII ! scope="col" | ! scope="col" | |- | Copy{{efn|name=BSC}} | {{n/a}} | F7 | 37 | 7 | Copy from one device buffer to another, e.g., from a display to a printer |- | Erase All Unprotected{{sfn|3270 Data Stream|loc=Erase All Unprotected (EAU) Command|p=3-7}} | 0F | 6F | 3F | ? | Erase all unprotected fields and reset modified data tags |- | Erase/Write{{sfn|3270 Data Stream|loc=Erase/Write Command|p=3-6}} | 05 | F5 | 35 | 5 | Erase device buffer, then write WCC followed by orders and data |- | Erase/Write Alternate{{efn|Not available on 3271, 3272 or 3275|name=alternate}}{{sfn|3270 Data Stream|loc=Erase/Write Alternate Command|p=3-6}} | 0D | 7E | 3D | = | Erase device buffer, set alternate size, then write WCC followed by orders and data |- | No Operation | 03 | {{n/a}} | {{n/a}} | {{n/a}} | May be used to retrieve pending status |- | Read Buffer{{sfn|3270 Data Stream|loc=Read Buffer Command|pp=3-11β3-12}} | 02 | F2 | 22 | 2 | Read entire device buffer, including attributes |- | Read Modified{{sfn|3270 Data Stream|loc=Read Modified Command|pp=3-12β3-13}} | 06 | F6 | 36 | 6 | Read AID, cursor and, except for short read, modified fields from device |- | Read Modified All{{sfn|3270 Data Stream|loc=Read Modified All Command|pp=3-13β3-14}} | {{n/a}} | 6E | 3E | : | Read AID, cursor and modified fields from device; no short read |- | Select{{sfn|3274 Description|loc=Select Command (3274 B Units)|p=1-70}} | 0B | {{n/a}} | {{n/a}} | {{n/a}} | Transfer data from device to control unit with channel disconnected |- | Select RB{{efn|Only available on 3274 D models and 3174|name=3274D}}{{sfn|3274 Description|loc=Select Read Buffer (RB) Command (3274 D Units)|p=1-71}} | 1B | {{n/a}} | {{n/a}} | {{n/a}} | Select Read Buffer;<br />may only be chained to Read Buffer |- | Select RBP{{efn|name=3274D}}{{sfn|3274 Description|loc=Select Read Buffer from Position (RBP) Command (3274 D Units)|p=1-72}} | 3B | {{n/a}} | {{n/a}} | {{n/a}} | Select Read Buffer from Position;<br />may only be chained to Read Buffer |- | Select RM{{efn|name=3274D}}{{sfn|3274 Description|loc=Select Read Modified (RM) Command (3274 D Units)|p=1-71}} | DB | {{n/a}} | {{n/a}} | {{n/a}} | Select Read Modified |- | Select RMP{{efn|name=3274D}}{{sfn|3274 Description|loc=Select Read Modified from Position (RMP) Command (3274 D Units)|p=1-71}} | 2B | {{n/a}} | {{n/a}} | {{n/a}} | Select Read Modified from Position |- | Select WRT{{efn|name=3274D}}{{sfn|3274 Description|loc=Select WRT Command (3274 D Units)|p=1-72}} | 4B | {{n/a}} | {{n/a}} | {{n/a}} | Select WRT Command<br />May only be chained to a Write or Write Structured Field |- | Sense{{sfn|3274 Description|loc=Sense Command (3274 Band D Units)|p=1-73}} | 04 | {{n/a}} | {{n/a}} | {{n/a}} | Retrieve error information after unit check |- | Sense ID{{efn|name=alternate}}{{sfn|3274 Description|loc=Sense ID Command (3274 Band D Units)|p=1-73}} | E4 | {{n/a}} | {{n/a}} | {{n/a}} | Retrieve control unit identification |- | Write{{sfn|3270 Data Stream|loc=Write Command|p=3-5}} | 01 | F1 | 31 | 1 | Write WCC followed by orders and data |- | Write Structured Field{{efn|name=alternate}}{{efn|name=extended}}{{sfn|3270 Data Stream|loc=Write Structured Field Command|p=3-7}} | 11 | F3 | {{n/a}} | 3 | Write Structured Field |- | colspan=6 | For remote 3270s non-significant bits are set so that the command forms a valid EBCDIC (or ASCII) character. |}
Summary:
Please note that all contributions to Niidae Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
Encyclopedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Search
Search
Editing
IBM 3270
(section)
Add topic