Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Special pages
Niidae Wiki
Search
Search
Appearance
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
Microfluidics
(section)
Page
Discussion
English
Read
Edit
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
View history
General
What links here
Related changes
Page information
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
=== Open microfluidics === The behavior of fluids and their control in open microchannels came into focus around 2005<ref name="Melinvan der Wijngaart2005">{{cite journal | vauthors = Melin J, van der Wijngaart W, Stemme G | title = Behaviour and design considerations for continuous flow closed-open-closed liquid microchannels | journal = Lab on a Chip | volume = 5 | issue = 6 | pages = 682–686 | date = June 2005 | pmid = 15915262 | doi = 10.1039/b501781e | url = http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-14775 }}</ref> and applied in air-to-liquid sample collection<ref name="FriskRönnholm2006">{{cite journal | vauthors = Frisk T, Rönnholm D, van der Wijngaart W, Stemme G | title = A micromachined interface for airborne sample-to-liquid transfer and its application in a biosensor system | journal = Lab on a Chip | volume = 6 | issue = 12 | pages = 1504–1509 | date = December 2006 | pmid = 17203153 | doi = 10.1039/B612526N | url = http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-14188 }}</ref><ref name="FriskSandström2008">{{cite journal | vauthors = Frisk T, Sandström N, Eng L, van der Wijngaart W, Månsson P, Stemme G | title = An integrated QCM-based narcotics sensing microsystem | journal = Lab on a Chip | volume = 8 | issue = 10 | pages = 1648–1657 | date = October 2008 | pmid = 18813386 | doi = 10.1039/b800487k | url = http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-14189 }}</ref> and chromatography.<ref name="JacksénFrisk2007">{{cite journal | vauthors = Jacksén J, Frisk T, Redeby T, Parmar V, van der Wijngaart W, Stemme G, Emmer A | title = Off-line integration of CE and MALDI-MS using a closed-open-closed microchannel system | journal = Electrophoresis | volume = 28 | issue = 14 | pages = 2458–2465 | date = July 2007 | pmid = 17577881 | doi = 10.1002/elps.200600735 | s2cid = 16337938 | doi-access = free }}</ref> In [[open microfluidics]], at least one boundary of the system is removed, exposing the fluid to air or another interface (i.e. liquid).<ref name=":1">{{cite book| vauthors = Berthier J, Brakke KA, Berthier E |date=2016-08-01|title=Open Microfluidics|doi=10.1002/9781118720936|isbn=9781118720936}}</ref><ref>{{cite journal | vauthors = Pfohl T, Mugele F, Seemann R, Herminghaus S | title = Trends in microfluidics with complex fluids | journal = ChemPhysChem | volume = 4 | issue = 12 | pages = 1291–1298 | date = December 2003 | pmid = 14714376 | doi = 10.1002/cphc.200300847 | url = https://ris.utwente.nl/ws/files/6488126/trends_in_microfluidics.pdf }}</ref><ref name=":2">{{cite journal | vauthors = Kaigala GV, Lovchik RD, Delamarche E | title = Microfluidics in the "open space" for performing localized chemistry on biological interfaces | journal = Angewandte Chemie | volume = 51 | issue = 45 | pages = 11224–11240 | date = November 2012 | pmid = 23111955 | doi = 10.1002/anie.201201798 }}</ref> Advantages of open microfluidics include accessibility to the flowing liquid for intervention, larger liquid-gas surface area, and minimized bubble formation.<ref>{{cite journal |last1=Lade |first1=R. K. |last2=Jochem |first2=K. S. |last3=Macosko |first3=C. W. |last4=Francis |first4=L. F. |date=2018 |title=Capillary Coatings: Flow and Drying Dynamics in Open Microchannels |url=https://doi.org/10.1021/acs.langmuir.8b00811 |journal=Langmuir |volume=34 |issue=26 |pages=7624–7639 | pmid=29787270 | doi=10.1021/acs.langmuir.8b00811}}</ref><ref name=":1" /><ref name=":2" /><ref>{{cite journal | vauthors = Li C, Boban M, Tuteja A | title = Open-channel, water-in-oil emulsification in paper-based microfluidic devices | journal = Lab on a Chip | volume = 17 | issue = 8 | pages = 1436–1441 | date = April 2017 | pmid = 28322402 | doi = 10.1039/c7lc00114b | s2cid = 5046916 }}</ref> Another advantage of open microfluidics is the ability to integrate open systems with surface-tension driven fluid flow, which eliminates the need for external pumping methods such as peristaltic or syringe pumps.<ref name=":4">{{cite journal | vauthors = Casavant BP, Berthier E, Theberge AB, Berthier J, Montanez-Sauri SI, Bischel LL, Brakke K, Hedman CJ, Bushman W, Keller NP, Beebe DJ | display-authors = 6 | title = Suspended microfluidics | journal = Proceedings of the National Academy of Sciences of the United States of America | volume = 110 | issue = 25 | pages = 10111–10116 | date = June 2013 | pmid = 23729815 | pmc = 3690848 | doi = 10.1073/pnas.1302566110 | doi-access = free | bibcode = 2013PNAS..11010111C }}</ref> Open microfluidic devices are also easy and inexpensive to fabricate by milling, thermoforming, and hot embossing.<ref>{{cite journal | vauthors = Guckenberger DJ, de Groot TE, Wan AM, Beebe DJ, Young EW | title = Micromilling: a method for ultra-rapid prototyping of plastic microfluidic devices | journal = Lab on a Chip | volume = 15 | issue = 11 | pages = 2364–2378 | date = June 2015 | pmid = 25906246 | pmc = 4439323 | doi = 10.1039/c5lc00234f }}</ref><ref>{{cite journal|vauthors = Truckenmüller R, Rummler Z, Schaller T, Schomburg WK|date=2002-06-13|title=Low-cost thermoforming of micro fluidic analysis chips|journal=Journal of Micromechanics and Microengineering|volume=12|issue=4|pages=375–379|doi=10.1088/0960-1317/12/4/304|issn=0960-1317|bibcode=2002JMiMi..12..375T|s2cid=250860338 }}</ref><ref>{{cite journal | vauthors = Jeon JS, Chung S, Kamm RD, Charest JL | title = Hot embossing for fabrication of a microfluidic 3D cell culture platform | journal = Biomedical Microdevices | volume = 13 | issue = 2 | pages = 325–333 | date = April 2011 | pmid = 21113663 | pmc = 3117225 | doi = 10.1007/s10544-010-9496-0 }}</ref><ref>{{cite journal | vauthors = Young EW, Berthier E, Guckenberger DJ, Sackmann E, Lamers C, Meyvantsson I, Huttenlocher A, Beebe DJ | display-authors = 6 | title = Rapid prototyping of arrayed microfluidic systems in polystyrene for cell-based assays | journal = Analytical Chemistry | volume = 83 | issue = 4 | pages = 1408–1417 | date = February 2011 | pmid = 21261280 | pmc = 3052265 | doi = 10.1021/ac102897h }}</ref> In addition, open microfluidics eliminates the need to glue or bond a cover for devices, which could be detrimental to capillary flows. Examples of open microfluidics include open-channel microfluidics, rail-based microfluidics, [[Paper-based microfluidics|paper-based]], and thread-based microfluidics.<ref name=":1" /><ref name=":4" /><ref>{{cite journal | vauthors = Bouaidat S, Hansen O, Bruus H, Berendsen C, Bau-Madsen NK, Thomsen P, Wolff A, Jonsmann J | display-authors = 6 | title = Surface-directed capillary system; theory, experiments and applications | journal = Lab on a Chip | volume = 5 | issue = 8 | pages = 827–836 | date = August 2005 | pmid = 16027933 | doi = 10.1039/b502207j | s2cid = 18125405 }}</ref> Disadvantages to open systems include susceptibility to evaporation,<ref>{{cite journal | vauthors = Kachel S, Zhou Y, Scharfer P, Vrančić C, Petrich W, Schabel W | title = Evaporation from open microchannel grooves | journal = Lab on a Chip | volume = 14 | issue = 4 | pages = 771–778 | date = February 2014 | pmid = 24345870 | doi = 10.1039/c3lc50892g }}</ref> contamination,<ref>{{cite book | vauthors = Ogawa M, Higashi K, Miki N | title = 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)| chapter = Development of hydrogel microtubes for microbe culture in open environment | volume = 2015 | issue = 6 | pages = 5896–5899 | date = August 2015 | pmid = 26737633 | pmc = | doi = 10.1109/EMBC.2015.7319733 | isbn = 978-1-4244-9271-8| s2cid = 4089852}}</ref> and limited flow rate.<ref name=":2" />
Summary:
Please note that all contributions to Niidae Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
Encyclopedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Search
Search
Editing
Microfluidics
(section)
Add topic