Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Special pages
Niidae Wiki
Search
Search
Appearance
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
Fourier-transform spectroscopy
(section)
Page
Discussion
English
Read
Edit
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
View history
General
What links here
Related changes
Page information
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
==Conceptual introduction== ===Measuring an emission spectrum=== [[File:Spectrum of blue flame.svg|thumb|300 px| An example of a [[spectrum]]: The spectrum of light emitted by the blue flame of a [[butane torch]]. The horizontal axis is the [[wavelength]] of light, and the vertical axis represents how much light is emitted by the torch at that wavelength.]] One of the most basic tasks in [[spectroscopy]] is to characterize the [[spectrum]] of a light source: how much light is emitted at each different wavelength. The most straightforward way to measure a spectrum is to pass the light through a [[monochromator]], an instrument that blocks all of the light ''except'' the light at a certain wavelength (the un-blocked wavelength is set by a knob on the monochromator). Then the intensity of this remaining (single-wavelength) light is measured. The measured intensity directly indicates how much light is emitted at that wavelength. By varying the monochromator's wavelength setting, the full spectrum can be measured. This simple scheme in fact describes how ''some'' spectrometers work. Fourier-transform spectroscopy is a less intuitive way to get the same information. Rather than allowing only one wavelength at a time to pass through to the detector, this technique lets through a beam containing many different wavelengths of light at once, and measures the ''total'' beam intensity. Next, the beam is modified to contain a ''different'' combination of wavelengths, giving a second data point. This process is repeated many times. Afterwards, a computer takes all this data and works backwards to infer how much light there is at each wavelength. To be more specific, between the light source and the detector, there is a certain configuration of mirrors that allows some wavelengths to pass through but blocks others (due to [[wave interference]]). The beam is modified for each new data point by moving one of the mirrors; this changes the set of wavelengths that can pass through. As mentioned, computer processing is required to turn the raw data (light intensity for each mirror position) into the desired result (light intensity for each wavelength). The processing required turns out to be a common algorithm called the [[Fourier transform]] (hence the name, "Fourier-transform spectroscopy"). The raw data is sometimes called an "interferogram". Because of the existing computer equipment requirements, and the ability of light to analyze very small amounts of substance, it is often beneficial to automate many aspects of the sample preparation. The sample can be better preserved and the results are much easier to replicate. Both of these benefits are important, for instance, in testing situations that may later involve legal action, such as those involving drug specimens.<ref>Semiautomated depositor for infrared microspectrometry http://www.opticsinfobase.org/viewmedia.cfm?uri=as-57-9-1078&seq=0</ref> ===Measuring an absorption spectrum=== [[File:FTIR-interferogram.svg|thumb|An "interferogram" from a Fourier-transform spectrometer. This is the "raw data" which can be [[Fourier transform|Fourier-transformed]] into an actual spectrum. The peak at the center is the ZPD position ("zero path difference"): Here, all the light passes through the [[Michelson interferometer|interferometer]] because its two arms have equal length.]] The method of Fourier-transform spectroscopy can also be used for [[absorption spectroscopy]]. The primary example is "[[Fourier-transform infrared spectroscopy|FTIR Spectroscopy]]", a common technique in chemistry. In general, the goal of absorption spectroscopy is to measure how well a sample absorbs or transmits light at each different wavelength. Although absorption spectroscopy and emission spectroscopy are different in principle, they are closely related in practice; any technique for emission spectroscopy can also be used for absorption spectroscopy. First, the emission spectrum of a broadband lamp is measured (this is called the "background spectrum"). Second, the emission spectrum of the same lamp ''shining through the sample'' is measured (this is called the "sample spectrum"). The sample will absorb some of the light, causing the spectra to be different. The ratio of the "sample spectrum" to the "background spectrum" is directly related to the sample's absorption spectrum. Accordingly, the technique of "Fourier-transform spectroscopy" can be used both for measuring emission spectra (for example, the emission spectrum of a star), ''and'' absorption spectra (for example, the absorption spectrum of a liquid).
Summary:
Please note that all contributions to Niidae Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
Encyclopedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Search
Search
Editing
Fourier-transform spectroscopy
(section)
Add topic